Thermador REF30 Installation Instructions Manual
Thermador REF30 Installation Instructions Manual

Thermador REF30 Installation Instructions Manual

30" electric & dual-fuel free-standing and slide-in ranges
Hide thumbs Also See for REF30:

Advertisement

INSTALLATION INSTRUCTIONS MANUAL
30" FREE-STANDING and SLIDE-IN RANGES
DUAL-FUEL MODELS RDF30, RDFS30 & RDSS30
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
IMPORTANT:
INSTALLER:
OWNER:
WARNING:
AVERTISSEMENT:
IMPORTANT: LOCAL CODES VARY. INSTALLATION, ELECTRICAL CONNECTIONS
AND GROUNDING MUST COMPLY WITH ALL APPLICABLE CODES.
Check your local building codes for the proper method of
installation. In the U.S.A., if there are no applicable local codes,
this unit should be installed in accordance with the National Fuel
Gas Code #Z223.1-Current Issue, and the National Electrical
Code ANSI/NFPA No. 70 Current Issue. (In Canada, installation
must be in accordance with the CAN 1-B149.1 and .2 - Installation
Codes for Gas Burning Appliances and/ or local codes).
WARNING: If the information in this manual
is not followed exactly, a fire or explosion may
result causing property damage, personal
injury or death.
N Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
N
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
N Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
ELECTRIC MODELS REF30, RES30
Save these instructions for the local electrical inspector's use.
Please leave these Installation Instructions with this unit for the owner.
Please retain these instructions for future reference.
Before installing turn power OFF at the service panel. Lock service panel to prevent
power from being turned ON accidentally.
Avant l'installation, COUPER au tableau de service, et fermer a clef le tableau de service
pour empecher l'alimination d'etre allumée per hasard.
UL LISTED #159J
MOBILE home installation must conform with the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
{formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD (Part 280)} or, when such standard is
not applicable, the Standard for Manufactured Home Installations,
ANSI A255.1 / NFPA501A, or with local codes.
AVERTISSEMENT: Si l'information dans ce
manuel n'est pas suivie exactement, un feu ou
une explosion peut résulter et causer des dégâts
matèriels et des risques d'accidents, ou la mort.
N Ne pas emmagasiner ou utiliser de l'essence
ou des autres vapeurs inflammables et liquides
aux endroits de celui-ci ou aucun autre
appareil.
N CE QUI FAIRE SI VOUS SENTEZ LE GAZ
Ne pas essayer d'allumer aucun appareil
Ne pas toucher aucun interrupteur
électrique; ne pas utiliser aucun téléphone
dans votre bâtiment.
Appeler immédiatement votre fournisseur
de gaz du téléphone d'un voisin. Suivre
l'instruction du fournisseur de gaz.
Si vous ne pouvez pas contacter votre
fournisseur, téléphoner le service des
incendies.
N
L'installation et le service doivent être
exécutés par un installateur qualifié, une agence
de service ou le fournisseur de gaz.
1
I
FILE # E8719

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the REF30 and is the answer not in the manual?

Questions and answers

Summary of Contents for Thermador REF30

  • Page 1 UL LISTED #159J FILE # E8719 INSTALLATION INSTRUCTIONS MANUAL 30" FREE-STANDING and SLIDE-IN RANGES ELECTRIC MODELS REF30, RES30 DUAL-FUEL MODELS RDF30, RDFS30 & RDSS30 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these instructions for the local electrical inspector’s use.
  • Page 2: Table Of Contents

    350 CFM is Instructions were determined using Standard American base recommended. Thermador hoods rated at 350 CFM or cabinets measuring 36" high x 24" deep (see Figures 2 & 3). more when operated on High meet the above requirement and are recommended for this purpose.
  • Page 3: Ventilation And Cabinet Considerations

    VENTILATION AND CABINET CONSIDERATIONS Layout the remaining dimensions ATTENTION: Pour élimıner le positioned from the back of these CAUTION: To eliminate the risque de brûlures ou d’incendie notches. risk of burns or flre by reaching en atteindrant sur les unités de If nonstandard cabinets are used, care over heated surface units, cabinet la surface chauffés, I’espace...
  • Page 4 GAS CONNECTION (MODELS RDF30, RDFS30 AND RDSS301) GAS CONNECTION WARNING: Do not attempt any adjustment of the For gas units, a 1/2" N.P.T. wall gas supply can lie anywhere pressure regulator except conversion to propane. within the shaded area. (See Figure 4.) This will provide accessibility to the shut-off valve by removing the storage AVERTISSEMENT: Ne pas entreprener aucun drawer.
  • Page 5: Electrical Connections

    The power supply shall be connected to the range terminal 120/208 15 AMPS block compartment located in the lower left rear corner, accessible by removing the storage drawer below the oven. MODEL REF30, RES30 (See Figure 6.) VOLTS RATING CIRCUIT A.C.
  • Page 6 ELECTRICAL CONNECTION (ALL MODELS) Figure 9 – Wire Connection Figure 8 – Conductor Securement Figure 10a – 4-Wire Connection Ground Strap Figure 10b – 4-Wire Connection Neutral Wire The terminal provided will accept leads with ring terminals 4-WIRE LEAD CONNECTION or stripped conductors.
  • Page 7: Anti-Tip Warning

    ANTI-TIP WARNING WARNING WARNING RANGE TIPPING HAZARD • All ranges can tip and injury could result. • ALL RANGES CAN TIP To prevent accidental tipping of the range, attach it to the wall, floor or cabinet by • INJURY TO PERSONS installing the Anti-TIp Device supplied.
  • Page 8: Range Installation

    Thermador reserves the right to change specifications or design without notice. Some models are certified for use in Canada. Thermador is not responsible for products which are transported from the United States for use in Canada. Check with your local Canadian distributor or dealer.

This manual is also suitable for:

Res30Rdf30Rdfs30Rdss30

Table of Contents