5.
If you are using an extension cord
outdoors, make sure it is marked with
the suffix "W-A" ("W" in Canada) to
indicate it is acceptable for outdoor
use.
6.
Make sure the extension cord is
properly wired and in good electrical
condition. Always replace a damaged
extension cord or have it repaired by
a qualified electrician before using it.
7.
Protect the extension cords from
sharp objects, excessive heat, and
damp or wet areas.
RECOMMEndEd MInIMUM WIRE
gAUgE FOR EXTEnSIOn CORdS*
(120/240 VOLT)
nAMEpLATE
AMpERES
(at full load)
0 – 2.0
2.1 – 3.4
3.5 – 5.0
5.1 – 7.0
7.1 – 12.0
12.1 – 16.0
16.1 – 20.0
TABLE A
SKU 95914
For technical questions, please call 1-800-444-3353.

EXTEnSIOn CORd

LEngTh
18
18
18
18
18
18
18
16
18
18
16
14
18
16
14
12
18
14
12
10
14
12
10
-
12
10
-
-
* Based on limiting the line
voltage drop to five volts at
150% of the rated amperes.
V~
A
n 0 xxxx/min.
16
14
12
12
-
-
-
Symbology
Double Insulated
Canadian Standards Association
Underwriters Laboratories, Inc.
Volts Alternating Current
Amperes
No Load Revolutions per Minute
(RPM)
Page 5