Electric floor air conditioner portable type (12 pages)
Summary of Contents for Timberk AC TIM 07H S8ML
Page 1
(split system , in set of two units) /Models Air conditioner units for indoor installation AC TIM 07H S8ML AC TIM 18H S8ML AC TIM 09H S8ML AC TIM 24H S8ML AC TIM 12H S8ML Air conditioner units for outdoor installation...
21. Do not start or stop the unit by connecting or disconnecting electrical power. 19.To avoid electric shock, a damaged power cord should be replaced only in authorized service centers by qualified specialists. www.timberk.com Electric air conditioner (split system, in set of two units)
Net dimensions, outdoor unit (mm) 760x552x256 902x650x307 600x500x232 600x500x232 700x552x256 Packing dimensions, indoor unit (mm) 995x365x298 995x365x298 805×305×255 805×305×255 855×305×255 Packing dimensions, outdoor unit (mm) 863x598x376 1037x705x433 745x550x353 745x550x353 803x598x380 www.timberk.com Electric air conditioner (split system, in set of two units)
Batteries for remote control board - 2 pcs. User manual -1 piece Guarantee slip -1 piece Packing of indoor-installation unit -1 piece Packing of outdoor-installation unit -1 piece * not supplied www.timberk.com Electric air conditioner (split system, in set of two units)
Protect the board from water and In Auto mode the fan speed will change automatically. In dry mode the fan exposure to direct sunlight and heat sources. speed will remain unchanged Low . www.timberk.com Electric air conditioner (split system, in set of two units)
Unplug the conditioner. Remove the batteries from the remote control conditioner will start working in turbo mode for maximum cooling (in cool board. mode) or for maximum heating (in heat mode). www.timberk.com Electric air conditioner (split system, in set of two units)
The conditioner works, but A three-minute delay of compressor turning does not cool or heat the Wait a little room The air temperature is set incorrectly Set the temperature correctly www.timberk.com Electric air conditioner (split system, in set of two units)
Page 9
AC TIM 09H S8ML AC TIM 12H S8ML AC TIM 24H S8ML AC TIM 07H S8ML AC TIM 18H S8ML AC TIM 07H S8ML AC TIM 09H S8ML AC TIM 12H S8ML AC TIM 18H S8ML AC TIM 24H S8ML...
Page 11
«Auto», «High», «Middle», «Low». «Auto» «Low». «SWING». «TIMER». TEMP «SUPER». «ECO» (Economic). 2° 2° SLEEP SUPER ECO FEEL AUTO COOL HIGH «SLEEP» (Night Care). HEAT SWING TIMER ON TIMER OFF MODE 1° 1° TIMER SWING SLEEP «MODE». SUPER www.timberk. om...
Page 12
то включается режим Осушения 18°C если >26°C то включается режим Охлаждения 23°C Smart TIMER . Smart "-", "SLEEP Temp +/-, "-" +(-) 2. -2...+2 «SLEEP» (Night Care). (COOL, HEAT, FAN) 1° "ON/OFF". "MODE", (COOL), 1° (HEAT) (FAN) "TEMP" ( www.timberk. om...
Page 13
Очистите воздушный фильтр или Посторонние предметы загораживают теплопроизводительность воздухозаборную или воздуховыпускную решетку наружного блока Удалите посторонние предметы Кондиционер работает, но Действует трехминутная задержка не охлаждает и не включения компрессора Немного подождите обогревает помещение Неправильно задана температура воздуха Правильно задайте температуру www.timberk. om...
Need help?
Do you have a question about the AC TIM 07H S8ML and is the answer not in the manual?
Questions and answers