Unplug Stove Before Performing any Maintenance work
PROBLEM
Blowers will not operate
when the start switch is
depressed.
There is soot or fly ash in
the house.
APPENDIX A
TROUBLE-SHOOTING (CONT'D...)
CAUSE(S)
There is no power to the
stove.
There is no power to the con-
trol board.
The window is being cleaned
when the stove is operating.
There is leakage at the joints
between the combustion fan,
connection or exhaust pipe
connections. This will be evi -
denced by dust on the
impeller of the convection fan,
and in the heat exchanger
area.
The vacuum cleaner is leaking.
SOLUTIONS
Check that the stove is plugged in
to the wall outlet.
Check to see if your circuit breaker
has tripped.
Check the wire connections on the
high limit snap switch and Control
board.
Turn down the convection fan or
turn off stove before cleaning to
prevent dispersion of ash and soot
into the room.
Seal up any leaks in the exhaust
system with room temperature
vulcanizing silicone sealer (RTV).
DO NOT use a standard household
vacuum or "shop vac" as the filters
will leak the fine particles of ash.
Clean the stove with an approved
Ash Vacuum ONLY.