Whitfield Profile 20 FS Installation And Operation Manual page 43

Profile series free-standing and insert pellet-fired stoves
Table of Contents

Advertisement

SAFETY / LISTING LABEL - MODEL PROFILE
LISTED ROOM HEATER. PELLETIZED WOOD FUEL TYPE. ALSO
FOR USE IN MANUFACTURED (MOBILE) HOME, AND AS AN
INSERT FOR MASONRY FIREPLACES AND FACTORY BUILT
FIREPLACES, OR AS BUILT IN. MODEL: PROFILE 30-2, TESTED
TO: UL 1482 / ULC-S627 / ULC-S628 REPORT NO: 5515 (DEC.
1991) ASTME1509 REPORT NO: 476-1244 (MAR. 1996).
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION
INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION IN YOUR AREA. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER FIREPLACE. SEE LOCAL BUILDING CODE AND MANUFACTURER'S
INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A CHIMNEY THROUGH A COM-
BUSTIBLE WALL OR CEILING. THIS PELLET FIRED APPLIANCE HAS BEEN TESTED AND LISTED
FOR USE IN MANUFACTURED (MOBILE) HOMES IN ACCORDANCE WITH OREGON
ADMINISTRATIVE RULES 814-23-900 THROUGH 814-23-9O9.
OPERATE ONLY WITH FIREBRICKS IN PLACE. OPERATE ONLY WITH VIEWING DOOR AND ASH
REMOVAL DOOR CLOSED. INSPECT FLUE FREQUENTLY. CLEAN HEAT EXCHANGER AND FLUE
FREQUENTLY TO PREVENT ACCUMULATION OF SOOT. THE HEATER AND FLUE MUST BE IN
GOOD CONDITION. REQUIRED COMPONENTS: DAMPER SEALING PLATE FOR INSERT INSTAL-
LATIONS. USE 3"/75MM OR 4"/100MM MODEL PL CHIMNEY COMPONENTS. KEEP FURNISH-
INGS AND OTHER COMBUSTIBLE MATERIALS WELL AWAY FROM HEATER.
ELECTRICAL RATING: 115V 60Hz Less than 10 Amp
FUEL INPUT RATING: 4.5 Lbs./Hr. Max.
ROUTINE MAINTENANCE REMINDER
FREQUENCY OF CLEANING AND MAINTENANCE OF YOUR STOVE
DEPENDS ON THE ASH CONTENT OF THE PELLETS YOU BURN.
CHECK THE FOLLOWING PARTS OF YOUR STOVE WEEKLY FOR THE
FIRST MONTH TO DETERMINE CLEANING:
A. BURN GRATE
B. HEAT EXCHANGER TUBES
C. ASH TRAPS AND ASH PAN
SEE YOUR MANUAL AND/DEALER FOR MORE INFORMATION.
PROFILE 30-2
®
30 FS-2 AND PROFILE 30 INS-2
DO NOT REMOVE THIS LABEL
NUMÉRO DE SÊRIÊ/SERIAL WH-
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
MANUFACTURED (MOBILE) HOME OR RESIDENTIAL INSTALLATION
INSTALLED AS
FREESTANDING STOVE
HORIZONTAL FLUE-DIRECTLY THROUGH WALL
INSTALLATION
SIDEWALL TO UNIT
A*
6"/153 MM
BACKWALL TO UNIT
B
1"/26 MM
CORNER TO UNIT
C
1"/26 MM
ALCOVE TO FUEL HOPPER
D
6"/153 MM
DEPTH OF ALCOVE
E
16"/407 MM
FLUE TO WALL
F
3"/77MM
BACK WALL
ALCOVE BACK WALL
F
E
B
B
A
D
D
COMBUSTIBLE FLOOR MUST BE PROTECTED BY A
INSERT OR BUILT-IN
3/8" (10MM) MINIMUM MILLBOARD OR EQUIVALENT
NON-COMBUSTIBLE MATERIAL IN THE USA AND
CANADA EXTENDING BENEATH THE HEATER AND TO
J
I
THE FRONT AND SIDES AS INDICATED OR TO THE
NEAREST PERMITTED COMBUSTIBLE MATERIAL
H
(K=6" / 150MM).
G
INSTALLED AS AN INSERT
USE 3"/75MM / MODEL PL CHIMNEY COMPONENTS OR LISTED SINGLE
G. SIDE WALL
6"/153 MM
WALL CHIMNEY LINER. SEAL THE AREA BETWEEN THE FIREPLACE DAMPER
H. SIDE TRIM
1"/26 MM
AND THE INSERT FLUE. MAY BE INSTALLED IN A MASONRY FIREPLACE
I. TOP TRIM
1"/26 MM
THAT MEETS NATIONAL AND LOCAL BUILDING CODE REQUIREMENTS. (UBC
37 OR ULC S628) DO NOT REMOVE BRICKS OR MORTAR. MAY BE
J. ADJACENT
18"/458 MM
INSTALLED IN A FACTORY BUILT FIREPLACE. (UL 127 OR ULC S610) DO NOT
WALL
ALTER OR MODIFY THE FIREPLACE. REFER TO OWNERS MANUAL FOR
SPECIFIC INSTALLATION REQUIREMENTS. DO NOT ROUTE CORD BENEATH
OR OVER APPLIANCE. THE INSERT MODEL MAY BE FRAMED INTO A WALL
USING ZERO CLEARANCE KIT, CAT. NO. H0416.
60027304 REV E
*
UTILISER DES COMPOSANTS DE CHEMINÉE PL DE 3 po/75 MM OU UNE DOU-
BLURE DE CHEMINÉE MURALE SIMPLE. SCELLER L'ENDROIT SITUÉ ENTRE LE
REGISTRE DU FOYER ET LE CONDUIT DE FUMÉE DU FOYER ENCASTRABLE. PEUT
ÊTRE INSTALLÉ DANS UN FOYER DE MAÇONNERIE QUI EST CONFORME AUX
MUR LATÉRAL ADJACENT
REGLEMENTS DU CODE DU BÂTIMENT LOCAL ET NATIONAL. (UBC 37 OR ULC
S628) NE PAS ENLEVER, LES BRIQUES OU LE MORTIER. PEUT ÊTRE INSTALLÉ
DANS UN FOYER FABRIQUÉ EN USINE. (UL 127 OR ULC S610) NE PAS ALTERER
OU MODIFIER LE FOYER. CONSULTER LE GUIDE DU PROPRIÉTAIRE POUR
CONNAITRE LES EXIGENCES PRÉCISES D'INSTALLATION. NE PAS ACHEMINER LE
CORDON SOUS L'APPAREIL OU AU-DESSUS DE CELUI-CI. LE FOYER
ENCASTRABLE PEUT ÊTRE ENCADRÉ DANS UN MUR À L'AIDE DU NÉCESSAIRE
SANS DÉGAGEMENT, NO DE CAT. H0416.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
CAUTION:
FACES WHILE IN OPERA-
TION. DO NOT TOUCH. CON-
TACT MAY CAUSE SKIN
INTERIOR VERTICAL FLUE
INSTALLATION
BURNS. KEEP CHILDREN,
6"/153 MM
9"/229 MM
COMBUSTIBLE MATERIAL
1"/26 MM
6"/153 MM
N/A
AND FURNISHINGS A CONSIDERABLE DIS-
3"/77 MM
TANCE AWAY. SEE NAMEPLATE AND
ADJACENT WALL
INSTRUCTIONS. TYPE OF FUEL: PEL-
C
F
LETIZED WOOD FUEL ONLY.
C
A* ON RIGHT SIDE OF UNIT (AS VIEWED FROM FRONT), MAINTAIN A 5"
MINIMUM CLEARANCE TO ALLOW FOR PROPER DAMPER OPERATION.
K
K
K
K
PROFILE 30-2
A* Maintenir un dégagement minimum de 5 po sur le côté droit de
l'appareil (lorsque vous le regardez de l'avant).
HOT SUR-
FREESTAND
INSERT
Manufactured Listee:
Lennox Hearth Products; 1110 W. Taft Ave.;
Orange CA USA
Manufactured At: Juarez, Mexico
Product of Mexico
Listee De Fabricant:
Lennox Hearth Products; 1110 W. Taft Ave.;
Orange CA USA
Construit À: Juarez, Mexico
Produit De Mexique
43

Advertisement

Table of Contents
loading

Table of Contents