Tascam MA-AD8 User Manual
Tascam MA-AD8 User Manual

Tascam MA-AD8 User Manual

Digital mic amplifier

Advertisement

»
MA-AD8
Digital Mic Amplifier
Ü
ÿ
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert
the user to the presence of uninsulated "dangerous voltage" within the product's enclosure
that may be of sufficient magnitude to constitute a risk of electric shock to persons..
The exclamation point within an equilateral triangle is intended to alert the user to the pres-
Ÿ
ence of important operating and maintenance (servicing) instructions in the literature
accompanying the appliance.
This appliance has a serial number
located on the rear panel. Please record
the model number and serial number
and retain them for your records.
Model number
Serial number
OWNER'S MANUAL
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT
REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS
INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
WARNING: TO PREVENT FIRE OR SHOCK
HAZARD, DO NOT EXPOSE THIS
APPLIANCE TO RAIN OR MOISTURE.
D00444800A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MA-AD8 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tascam MA-AD8

  • Page 1 » D00444800A MA-AD8 Digital Mic Amplifier OWNER’S MANUAL CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT Ü REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. ÿ The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage”...
  • Page 2: Important Safety Precautions

    When replacing the fuse only a correctly rated approved type Funkstörungen versursachen ; in diesem Fall kann vom should be used and be sure to re-fit the fuse cover. Betrieber verlang werden, angemessene Maßnahmen durchzuführen und dafür aufzukommen. DOUBT — CONSULT COMPETENT ELECTRICIAN. TASCAM MA-AD8...
  • Page 3: Important Safety Instructions

    (including amplifiers) supporting structure, grounding of the lead-in wire to an antenna discharge that produce heat. unit, size of grounding conductors, location of antenna-discharge unit, con- nection to grounding electrodes, and requirements for the grounding elec- trode. TASCAM MA-AD8...
  • Page 4: Front Panel

    The source of the output to one of the TDIF-1 connec- The word clock source for the MA-AD8 may be either tors may be selected, in pairs of channels, as either the of the two TDIF-1 connections, or an external inde- analog inputs or the other TDIF-1 connector.
  • Page 5: Mic Inputs

    MA-AD8 Digital Mic Amplifier the DIGITAL I/O2 connector, and cannot be When one of these switches is in the up position, the signals passed to the DIGITAL I/O1 connector for the rerouted. corresponding channels will be the appropriate mic inputs (the XLR connectors on the rear panel).
  • Page 6 3. DTRS recorder EWORD THRU The INPUT switches 5 of the MA-AD8 are set to the This BNC connector echoes the clock signal received at the WORD IN e connector. If no device is con- TDIF-1 setting and the tape tracks are replayed into...
  • Page 7: Specifications

    TDIF-1 replayed digital tracks from the DTRS recorder. Sampling frequency 44.1 kHz, 48 kHz, ±6% The advantage of using the MA-AD8 in this situation is that the digital audio cabling is permanent—no dis- A/D resolution 20 bit connection and re-connection of cables needs to be...
  • Page 8: Block Diagram

    MA-AD8 Digital Mic Amplifier 1.4.2 Block diagram TEAC CORPORATION Phone: (0422) 52-5082 3-7-3, Nakacho, Musashino-shi, Tokyo 180-8550, Japan TEAC AMERICA, INC. Phone: (213) 726-0303 7733 Telegraph Road, Montebello, California 90640 TEAC CANADA LTD. Phone: 905-890-8008 Facsimile: 905-890-9888 5939 Wallace Street, Mississauga, Ontario L4Z 1Z8, Canada TEAC MEXICO, S.A.

Table of Contents