General Information

Electrical Requirements

To ensure proper ventilation for your refrigerator,
allow for a 1/2" (1.25 cm) space on each side and
at the top. Allow 1" (2.5 cm) of space behind the
refrigerator. If your refrigerator has an ice maker,
allow extra space at the back for the water line
connections. When installing your refrigerator next
to a fixed wall, leave a 2-3/4" (7.0 cm) minimum
space between the refrigerator and wall to allow
the door to swing open.
Overhead View
Wall
1/2"
(1.27 cm)
2-3/4"
(6.99 cm)
Before you move your refrigerator to its final
location, it is important to make sure you have
Door
the proper electrical connection.
Recommended Grounding Method
Moving Unit
A 115 Volt, 60 Hz., AC only 15- or 20-amp fused,
• DO NOT transport the refrigerator on its side. If
grounded electrical supply is required. It is
an upright position is not possible, lay the
recommended that a separate circuit serving only
refrigerator on its back. Allow refrigerator to sit
your refrigerator be provided. Use an outlet that
upright for approximately 30 minutes before
cannot be turned off by a switch. DO NOT use an
plugging it in to assure oil returns to the
extension cord.
compressor. Plugging the refrigerator in
immediately may cause damage to internal
NOTE: Before performing any type of installation,
parts.
cleaning, or removing a light bulb, turn the
• Use an appliance dolly when moving
cooling OFF. Disconnect the refrigerator from the
refrigerator. ALWAYS truck refrigerator from its
electrical source. When you are finished,
side or back - NOT from its front.
reconnect the refrigerator to the electrical source
• Cover outside finish of refrigerator during
and turn cooling on.
transport by wrapping cabinet in blankets
or inserting padding between the refrigerator
and dolly.
• Secure refrigerator to dolly firmly with straps or
bungee cords. Thread straps through handles
when possible. DO NOT overtighten.
Overtightening restraints may dent or damage
outside finish.
10
General Information

Water Supply Requirements

A cold water supply with water pressure of
Reverse Osmosis Water Supply (cont.)
between 35 and 120 psi (241 and 827 kPa) is
• If your refrigerator has a water filter, it may
required to operate the water dispenser and ice
maker. If you have questions about your water
pressure, call a licensed, qualified plumber.
Reverse Osmosis Water Supply
If you have questions about your water pressure,
IMPORTANT: The pressure of the water supply
call a licensed, qualified plumber.
coming out of a reverse osmosis system going to
the water inlet valve of the refrigerator needs to
be between 35 and 120 psi (241 and 827 kPa).
If a reverse osmosis water filtration system is
connected to your cold water supply, the water
pressure to the reverse osmosis system needs to
be a minimum of 40 to 60 psi (276 to 414 kPa).
If the water pressure to the reverse osmosis
system is less than 40 to 60 psi (276 to 414 kPa):
• Check to see whether the sediment filter in the
reverse osmosis system is blocked. Replace the
filter if necessary.
• Allow the storage tank on the reverse osmosis
system to refill after heavy usage.
11
further reduce the water pressure when used in
conjunction with a reverse osmosis system.
Remove the water filter.