Mitsubishi Electric SUZ-KA25VAH.TH Data Book page 41

Split-type, heat pump air conditioners
Hide thumbs Also See for SUZ-KA25VAH.TH:
Table of Contents

Advertisement

PERFORMANCE DATA
COOLING operation Rated frequency 80Hz
SEZ-KA50VA.TH / SUZ-KA50VA.TH
CAPACITY : 5.0(kW) INPUT : 1780(W) SHF : 0.75
INDOOR INDOOR
D.B.(;) W.B.(;)
Q
SHC SHF INPUT
21
18
4.90
2.79
21
20
5.15
2.32
22
18
4.90
2.99
22
20
5.15
2.52
22
22
5.45
2.02
23
18
4.90
3.19
23
20
5.15
2.73
23
22
5.45
2.23
24
18
4.90
3.38
24
20
5.15
2.94
24
22
2.45
5.45
24
24
5.75
1.90
25
20
5.15
3.14
25
22
5.45
2.67
25
24
5.75
2.13
26
18
4.90
3.77
26
20
3.35
5.15
26
22
5.45
2.89
26
24
5.75
2.36
26
26
6.05
1.75
27
18
4.90
3.97
27
20
5.15
3.55
27
22
5.45
3.11
27
24
5.75
2.59
27
26
6.05
2.00
28
18
4.90
4.17
20
28
5.15
3.76
28
22
5.45
3.32
28
24
5.75
2.82
28
26
6.05
2.24
29
18
4.90
4.36
29
20
5.15
3.97
29
22
5.45
3.54
29
24
3.05
5.75
29
26
6.05
2.48
30
18
4.90
4.56
30
20
5.15
4.17
30
22
5.45
3.76
30
24
5.75
3.28
30
26
6.05
2.72
31
18
4.90
4.75
31
20
5.15
4.38
31
22
5.45
3.98
31
24
5.75
3.51
31
26
6.05
2.96
32
18
4.90
4.95
32
20
5.15
4.58
32
22
5.45
4.20
32
24
5.75
3.74
32
26
6.05
3.21
NOTE
Q : Total capacity (kW)
SHC : Sensible heat capacity (kW)
OUTDOOR D.B.(;)
35
Q
SHC SHF INPUT
0.57
1744
4.50
2.57
0.45
1816
4.80
2.16
0.61
1744
4.50
2.75
0.49
1816
4.80
2.35
1.89
0.37
1887
5.10
0.65
1744
4.50
2.93
0.53
1816
4.80
2.54
0.41
1887
5.10
2.09
0.69
1744
4.50
3.11
0.57
1816
4.80
2.74
5.10
2.30
0.45
1887
0.33
1958
5.40
1.78
0.61
1816
4.80
2.93
0.49
1887
5.10
2.50
0.37
1958
5.40
2.00
0.77
1744
4.50
3.47
0.65
1816
4.80
3.12
0.53
1887
5.10
2.70
0.41
1958
5.40
2.21
0.29
2029
5.70
1.65
0.81
1744
4.50
3.65
3.31
0.69
1816
4.80
0.57
1887
5.10
2.91
0.45
1958
5.40
2.43
0.33
2029
5.70
1.88
0.85
1744
4.50
3.83
0.73
1816
4.80
3.50
5.10
3.11
0.61
1887
0.49
1958
5.40
2.65
0.37
2029
5.70
2.11
0.89
1744
4.50
4.01
0.77
1816
4.80
3.70
0.65
1887
5.10
3.32
1958
5.40
2.86
0.53
0.41
2029
5.70
2.34
0.93
1744
4.50
4.19
0.81
1816
4.80
3.89
0.69
1887
5.10
3.52
3.08
0.57
1958
5.40
0.45
2029
5.70
2.57
0.97
1744
4.50
4.37
0.85
1816
4.80
4.08
0.73
1887
5.10
3.72
0.61
1958
5.40
3.29
2.79
0.49
2029
5.70
1.01
1744
4.50
4.55
0.89
1816
4.80
4.27
0.77
1887
5.10
3.93
0.65
1958
5.40
3.51
0.53
2029
5.70
3.02
SHF : Sensible heat factor
INPUT : Total power input (W)
40
Q
SHC SHF INPUT
0.57
1851
4.15
2.37
0.45
1905
4.45
2.00
0.61
1851
4.15
2.53
0.49
1905
4.45
2.18
0.37
1994
4.75
1.76
0.65
1851
4.15
2.70
0.53
1905
4.45
2.36
0.41
1994
4.75
1.95
0.69
1851
4.15
2.86
2.54
0.57
1905
4.45
0.45
1994
4.75
2.14
0.33
2047
5.10
1.68
0.61
1905
4.45
2.71
0.49
1994
4.75
2.33
0.37
2047
5.10
1.89
4.15
3.20
0.77
1851
0.65
1905
4.45
2.89
0.53
1994
4.75
2.52
0.41
2047
5.10
2.09
0.29
2118
5.35
1.55
0.81
1851
4.15
3.36
1905
4.45
3.07
0.69
0.57
1994
4.75
2.71
0.45
2047
5.10
2.30
0.33
2118
5.35
1.77
0.85
1851
4.15
3.53
3.25
0.73
1905
4.45
0.61
1994
4.75
2.90
0.49
2047
5.10
2.50
0.37
2118
5.35
1.98
0.89
1851
4.15
3.69
0.77
1905
4.45
3.43
3.09
0.65
1994
4.75
0.53
2047
5.10
2.70
0.41
2118
5.35
2.19
0.93
1851
4.15
3.86
0.81
1905
4.45
3.60
0.69
1994
4.75
3.28
5.10
2.91
0.57
2047
0.45
2118
5.35
2.41
0.97
1851
4.15
4.03
0.85
1905
4.45
3.78
0.73
1994
4.75
3.47
0.61
2047
5.10
3.11
0.49
2118
5.35
2.62
1.01
1851
4.15
4.19
0.89
1905
4.45
3.96
0.77
1994
4.75
3.66
0.65
2047
5.10
3.32
2.84
0.53
2118
5.35
DB : Dry-bulb temperature
WB : Wet-bulb temperature
41
46
0.57
1922
0.45
2011
0.61
1922
0.49
2011
0.37
2065
0.65
1922
0.53
2011
0.41
2065
0.69
1922
2011
0.57
0.45
2065
0.33
2136
0.61
2011
0.49
2065
0.37
2136
0.77
1922
0.65
2011
0.53
2065
0.41
2136
0.29
2207
0.81
1922
0.69
2011
0.57
2065
0.45
2136
0.33
2207
0.85
1922
0.73
2011
0.61
2065
0.49
2136
0.37
2207
0.89
1922
0.77
2011
0.65
2065
0.53
2136
0.41
2207
0.93
1922
0.81
2011
0.69
2065
0.57
2136
0.45
2207
0.97
1922
0.85
2011
0.73
2065
0.61
2136
0.49
2207
1.01
1922
0.89
2011
0.77
2065
0.65
2136
2207
0.53