Connections
AC cord connection
Note:
Depending on the country of destination, relay type or direct attached type of the power supply cord is used.
How to remove terminal cover
To remove the terminal cover to connect a cable or other item, remove all 12 screws in bottom, middle, then top order
to prevent the terminal cover dropping off. Opening the terminal cover with some screws left on damages the terminal
cover.
Notes:
• After connection, check the cable is pulled out along the groove without overlapping, then tighten the all 12 screws
to attach the terminal cover correctly. Otherwise water enters inside and causes fi re, electric shock and product
damage.
• Water-proof washer is used for one screw with
through to attach the
• Make sure to read the "Terminal cover" (page iii) section for the correct handling of the terminal cover to use the
product properly.
10
Connect the AC cord
Line up and push together connectors A and B
so they are tight and then twist C until A and B
cannot be pulled apart.
A
C
marked screw.
B
Remove the screws (12) to
take out the terminal cover.
marked. To attach the terminal cover, let the water-proof washer
Disconnect the AC cord
Unscrew C and pull connector A and B apart.
C
A
Note:
When disconnecting the AC cord, be
absolutely sure to disconnect the AC
cord plug at the socket outlet first.
B