Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
In Massachusetts a licensed
plumber/gasfitter is required.
This appliance must be installed
with its own shut off valve and the
included gas pressure regulator.
Both the valve and the regulator
must be easily accessible to the
consumer to turn on or shut off the
gas supply after the appliance is
installed.
This appliance and its individual
shut off valve must be disconnected
from the gas supply during any
pressure testing of that system
performed in excess of
kPa), or isolated from the gas supply
line by closing its individual manual
shut off valve at test pressures equal
to or less than
Any pipe connections must be made
using a thread sealant approved for
gas connections. Failure to correctly
install these items could lead to a
gas leak and subsequent explosion.
14
1
/
psi (3.5
2
1
/
psi (3.5 kPa).
2
The gas connection must be made
in accordance with local codes or, in
the absence of local codes, with
-
the National Fuel Gas Code,
ANSI Z 21.1/NFPA 54
for the USA
or
-
the current Can/CGA B 149.1
and .2 Installation Codes for gas
burning appliances for Canada.
Make sure that the maximum gas
supply pressure before the gas
pressure regulator is never more than
1
/
psi for both natural gas or LP gas.
2
The minimum supply pressure to get
the required gas input is
4" w.c. for natural gas
10" w.c. for LP gas.