Maytag MGR8772WS1 Installation Instructions Manual page 9

30" (76.2 cm) freestanding gas ranges
Table of Contents

Advertisement

Available languages

Available languages

1. Remove the anti-tip bracket that is taped in the storage
drawer.
2. Determine which mounting method to use: floor or wall.
If you have a stone or masonry floor you can use the wall
mounting method.
3. Determine and mark the edge of the range in the cutout
space. The mounting bracket can be installed on either the
left side or right side of the cutout. Position mounting bracket
in cutout so that right (or left) edge of the bracket is
946" (14.5 ram) from the marked edge of the range, as shown.
A
B
A. Anti-tip bracket
B. Mark edge of range.
C. %6" (14.5 mm)
4. Drill two V8" (3.0 mm) holes that correspond to the bracket
holes of the determined mounting method. See below.
Floor Mounting
A. #12 x 1%" screws
B. Anti-tip bracket
Wall Mounting
5=
A. #12 x 1%" screws
B. Anti-tip bracket
Using the Phillips screwdriver, mount anti-tip bracket to the
wall or floor with the two #12 x 1%" screws provided.
Explosion
Hazard
Use a new CSA international approved
gas supply
line.
install a shut=off valve.
Securely
tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples
of a qualified
person include:
licensed heating
personnel,
authorized
gas company
personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
Typical flexible
connection
1. Apply pipe-joint compound
made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents