DRYER VENTING
If an Exhaust
Hood
Cannot
be Used
The outside end of main vent should have a sweep elbow
directed downward.
12" rain.
(305 ram)*
*Minimum
clearance above
any accumulation
of snow,
ice, or debris such as leaves
24" rain.
(610 rnm)
Multiple
Dryer Venting
A main vent can be used for venting a group of dryers. The
main vent should be sized to remove 5663 I/min. (200 CFM)
of air per dryen Large-capacity
lint screens of proper design
may be used in main vent if checked and cleaned frequently.
The room where the dryers are located should have make-up
air equal to or greater than CFM of all the dryers in the room.
Back-draft Damper Kit, Part No. 3391910, is available from
your distributor
and should be installed in the vent of each
dryer to keep exhausted air from returning
into dryers and to
keep exhaust in balance within main vent. Unobstructed
return
air openings are required.
Each vent should enter the main vent at an angle pointing in
the direction of the airflow. Vents entering from the opposite
side should be staggered to reduce the exhausted air from
interfering
with the other vents.
If main vent travels vertically through the roof, rather than
through wall, install a 180 ° sweep elbow on end of vent at least
2 ft. (610 mm) above surface of roof.
The opening in wall or roof shall have a diameter
:1/2" (13 mm)
larger than vent diameter. Vent should be centered in opening.
Do not install
screening
over
end of vent for best performance.
The maximum angle of each vent entering the main vent
should be no more than 30 °.
Keep air openings
free of dry cleaning
fluid
fumes.
Fumes
create
acids which,
when
drawn
through
the dryer
heating
units,
can damage
dryers
and items being
dried.
A clean-out
cover should
be located
on the main vent
for
periodic
cleaning
of the vent system.
GAS SUPPLY CONNECTION
Make Gas Connection
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1. Remove
red cap from
gas pipe on back of dryer.
2. Connect
gas supply
to dryer.
Use a pipe thread
compound
approved
for the type
of gas supplied.
If flexible
metal
tubing
is used, be certain
there
are no kinks.
If necessary
for service,
open the toe panel
by removing
the
21/4 '' hex-head
screws from
the bottom
of the panel. Then
lift up on the panel while
pulling
the bottom
of the panel
away from
the dryer.
3. Open the shut-off
valve
in the gas supply
line and make sure
the dryer
has its own gas supply
opened.
4. Test all connections
by brushing
on an approved
noncorrosive
leak-detection
solution.
Bubbles
will show
a leak. Correct
any leaks found.