Power
Supply Cord,
Four-wire
electrical
connection:
G
B
Y
F
_
/
A. Spadeterminalswithupturnedends E
B. Neutral
C. s/4"
(19
mm) UL-listedstrainrelief
D. Neutral(white)
E. Ringterminals
F. Groundwire
G. Ground prong
Four-wire power supply cord must have four,
No. 10 copper wires and match a four-wire
receptacle of NEMA Type 14-30R. The
fourth wire (ground conductor) must be
identified by a green cover and the neutral
conductor by a white cover.
5, Remove the center terminal block screw.
6. Remove the appliance neutral ground wire
from the external ground conductor screw.
Fasten under center, silver-colored
terminal block screw.
7. Connect the ground wire of the power
supply cord to the external ground
conductor screw. Tighten screw.
8. Connect the neutral wire (white or center)
of the power supply cord under the center
screw of the terminal block. Tighten
screw.
9. Connect the other wires to outer terminal
block screws. Tighten screws.
10, Tighten strain relief screws.
11. Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
A
............
,_
_'_
..... g
A. External ground conductor screw
B. Appliance neutral ground wire
C. Center terminal block screw
D. Outer terminal block screws
E. Strain relief screw
E Neutral (center wire)
G. Ground wire
15