Maytag MEDB700BW0 Installation Instructions Manual page 8

Electric dryer
Table of Contents

Advertisement

if your outlet looks like this:
Power supply cord 4-wire receptacle
(NEMA Type 14-30R):
Go to "4-Wire Power Supply Cord
Connection"
on this page.
Power supply cord 3-wire receptacle
(NEMA Type 10-30R):
Go to "3-Wire Power Supply Cord
Connection"
on page 9.
4=wire Power Supply Cord Connection
IMPORTANT: A 4-wire connection is requiredfor mobile homes and
where local codes do not permit the use of 3-wire connections.
4-wire receptacle (NEMA
type 14-30R)
Spade terminals with
upturned ends
4-prong plug
Ring terminals
Connect
neutral
ground
wire
and neutral
wire
Connect neutral ground wire (E) and neutral wire (white) (C)
of power supply cord under center terminal block screw (B).
Tighten screw.
Connect ground wire (F) (green or bare) of power supply cord
to external ground conductor
screw (A). Tighten screw.
Prepare to connect
neutral
ground
wire and neutral
wire
Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).
Connect
remaining
wires
Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover
into slot of dryer rear panel. Secure cover with hold-down
screw. Now, go to "Venting Requirements."