LG LRG3097ST Installation Instructions Manual page 11

Gas range
Hide thumbs Also See for LRG3097ST:
Table of Contents

Advertisement

INSTAllAIIONINSIRUCTIONS
7. ADJUST THE SURFACE BURNER LOW
FLAME(SIMMER) SETTING.
1) Light all surface burners.
2) Turn the knob on the burner being adjusted to
"LO".
3)
4)
Remove knob.
Insert a small, flat bladed screwdriver into the valve
shaft as shown in Fig. 1.
On right front valve for model LRG3097S there is a
secondary adjustment for the low flame for the
outer burners.
Using a small, flat bladed screwdriver insert into
the hole next to the valve stem to adjust outer
flame as shown in Fig. 2.
Turn the adjustment screw until the flame reaches
the desired size.
5) Replace the knob.
Note: Hold the valve shaft with one hand while turning
the screw for adjustment with the other.
f
Center adjustment screw
Adjustment screw next to
the valve shaft
Fig. 1
Fig. 2
6) Test The Flame Stability.
Test 1 : Turn the knob from "HI" to "LOW" quickly.
If the flame goes out, increase the flame size and test
again.
Test 2: With the burner on a "LOW" setting, open and
close the oven door quickly. If the flame is
extinguished by the air currents created by the door
movement, increase the flame height and test again.
7) Repeat steps 1-5 for each surface burner.