EVOC ERC-1005 User Manual

Industrial computer, afc terminal for metro

Advertisement

Quick Links

特种计算机
Industrial Computer
产品说明书
User Manual
ERC-1005
轨道交通 AFC 系统终端
AFC Terminal for Metro
Version: C01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ERC-1005 and is the answer not in the manual?

Questions and answers

Summary of Contents for EVOC ERC-1005

  • Page 1 特种计算机 Industrial Computer 产品说明书 User Manual ERC-1005 轨道交通 AFC 系统终端 AFC Terminal for Metro Version: C01...
  • Page 2: Legal Information

    Please pay attention to the following instructions: Warning EVOC product can only be used according to the descriptions within the manual, including the contents and the relevant technical documents. If the products or components from other companies are required, please get the recommendation and grant from EVOC first.
  • Page 3: Copyright Notice

    Trademarks EVOC is a registered trademark of EVOC Intelligent Technology Co., Ltd. Other product names mentioned herein are used for identification purposes only and may be trademark and/or registered trademarks of their respective companies.
  • Page 4: About This Manual

    About this manual Scope of the Manual The manual is appropriate for EVOC ERC-1005. Convention The term “the Board” or “the Product” within the manual stands for EVOC ERC-1005. Instructions Safety instructions To avoid property losses or individual injury, please pay attention to the safety instructions within the manual.
  • Page 5: Table Of Contents

    Contents 1. Product Introduction ....................1 1.1 Overview......................1 1.2 Product Specifications ..................1 2. Application Scheme ....................4 2.1 Transportation ....................4 2.2 Storage ......................4 2.3 Opening the Box and Initial Examination............5 2.4 Mounting Mode ....................5 3. Device Connection....................6 3.1 Notices before Connection................6 3.2 Product Grounding..................6 3.3 Connecting the Device to Power..............7 4.
  • Page 6 4.4.6 Display Connector ................14 4.4.7 GPIO ....................15 4.4.8 Mouse & Keyboard Connector (adopts standard 2-in-1 mouse & keyboard connector)................16 4.4.9 Serial Port ..................16 4.5 Operation Control ..................19 4.6 Status Indicator .....................19 5. Assembly and Maintenance ..................20 5.1 Overall Assembly Drawing................20 5.2 Installing the Cover..................21 5.3 Removal and Installation of Motherboard ............21 5.3.1 Installing the Motherboard..............21...
  • Page 7: Product Introduction

    ERC-1005 is the main control unit of the AFC system for metro, which is used as the main control unit of the AGM, TVM and BOM in AFC system. The PC complies with GB 9254-2008 and GB/T 17626-2008 standards.
  • Page 8 245mm(W) x 117.8mm(H) x 196mm(D) (excluding the hangers) 5.35Kg Weight Operating Temperature: Equipped with CF card and DOM PC: -20°C ~ 65°C; Temperature Equipped with mechanical hard disk PC:0℃~40℃; Storage Temperature: -40°C ~ 75°C; 5%~90% 40℃ (non-condensing) Humidity - 2 - ERC-1005...
  • Page 9 Mechanical  Anti-vibration: 5-17Hz/1.0mm amplitude; 17-200Hz/1.0g acceleration; Environment  Anti-shock: 10g acceleration, 11ms duration; Adaptability  Input Voltage/Current: DC12V ~ DC24V/max. 5A;  Typical Power Consumption: 12V@26W Power Feature  Maximum power consumption: 12V@34W (MaxPower 100%) ERC-1005 - 3 -...
  • Page 10: Application Scheme

    Under this circumstance, please make sure no water drop (condensation) is formed on the surface or interior of the device. If condensation is formed on the device, please wait for over twelve hours before connecting the device. - 4 - ERC-1005...
  • Page 11: Opening The Box And Initial Examination

    ● Please check whether the delivery contains the intact device and all of the independently ordered accessories. Please contact the customer service when any unconformity or transportation damages occur. 2.4 Mounting Mode □19″ Rack Mount ■Desktop □Embedded Panel ■Wall Mount □VESA Standard Arm □Portable □Others___________ ERC-1005 - 5 -...
  • Page 12: Device Connection

    The grounding terminal ① on the device (large surface or large area contact) shall be connected with the cabinet installed with the PC or the central grounding busbar device. minimum cross section area of the cable shall be no less than - 6 - ERC-1005...
  • Page 13: Connecting The Device To Power

    PC is lit and the PC is powered on. Danger Please disconnect the power and data cables during thunder storm. Note: To completely isolate the device from the power supply, please disconnect the power connector. ERC-1005 - 7 -...
  • Page 14: Instructions

    Instructions 4. Instructions 4.1 Product Outline 4.1.1 PC with Movable Scaffolding 4.1.2 PC with Fixation Apparatus - 8 - ERC-1005...
  • Page 15: Product Appearance And Installation Dimensions

    Instructions 4.2 Product Appearance and Installation Dimensions 4.2.1 PC with Movable Scaffolding Unit: mm ERC-1005 - 9 -...
  • Page 16: Pc With Fixation Apparatus

    Instructions 4.2.2 PC with Fixation Apparatus Unit: mm - 10 - ERC-1005...
  • Page 17: External Structure

    ⑬ switch RESET switch ⑭ PWR indicator ⑮ Assisting Handle ⑯ HDD indicator ⑰ VGA2 ⑱ Assisting Handle ⑲ COM3/COM4 ⑳ COM5/COM6 ○ COM7/COM8 ○ COM9 ○ GPIO1 ○ COM10 ○ GPIO2 ○ Assisting Handle ○ ERC-1005 - 11 -...
  • Page 18: Pin Definitions

    Power input terminal 4.4 Pin Definitions 4.4.1 Power Connector Signal Name 4.4.2 Audio Connector Signal Name LINE_OUT MIC_IN AUDIO 4.4.3 USB Port (USB1 ~ USB6 are standard USB ports) Signal Name USB_Data- USB1-2 USB_Data+ USB3-4 USB5-6 - 12 - ERC-1005...
  • Page 19: Lan Port (Lan1 And Lan2 Are Standard Connectors)

    Indicator (Green) Status Indicator Green 1000Mbps Blink Data being transmitted Orange 100Mbps No data being transmitted 10Mbps 4.4.5 Parallel Port (Adopts standard LPT connector) Signal Name Signal Name STB# AFD# ERR# INIT# SLIN# ACK# BUSY SLCT ERC-1005 - 13 -...
  • Page 20: Display Connector

    Note: this connector supports LVDS signals; please do not connect the DVI cable with the DVI connector on the display directly. Signal Name Signal Name LVDS_D2- LVDS_D2+ BKLTEN BKLTCTL LVDS_D1- LVDS_D1+ VDD_LCD VDD_LCD +12V LVDS1 LVDS_D0- LVDS_D0+ LVDS_CLK+ LVDS_CLK- +12V +12V - 14 - ERC-1005...
  • Page 21: Gpio

    DI23 DI24 DI25 DI26 DI27 GPIO1 DI28 DI29 DI30 DI31 +12V Signal Name Signal Name IDO1 IDO0 IDO2 IDO3 IDO4 IDO5 IDO6 IDO7 EO.GND EO.COM IDO10 IDO11 GPIO2 IDO12 IDO13 IDO14 IDO15 IDO16 IDO17 EI.COM1 EI.COM2 ERC-1005 - 15 -...
  • Page 22: Mouse & Keyboard Connector

    COM5 only support RS-232 mode, COM4 can switch among RS-232/RS-422/RS485 mode. COM6 ~ COM10 support RS-232 mode. The pin definitions are as follows: Signal Name RS-232 RS-422 RS-485 DCD# TXD- Data- TXD+ Data+ RXD+ DTR# RXD- COM1/COM2 COM6 ~ COM10 DSR# RTS# CTS# - 16 - ERC-1005...
  • Page 23 RS-422 RS-485 (Default) 1-3, 2-4 3-5, 4-6 3-5, 4-6 JP8/JP9/JP10 JP10 1-3, 2-4 3-5, 4-6 3-5, 4-6 Signal Name RS-232 RS-422 RS-485 Data- Data+ COM3/COM4/COM5 Note: the data transmission direction is controlled automatically under RS-485 mode. ERC-1005 - 17 -...
  • Page 24 Instructions RS-232/RS-422/RS-485 mode selection for COM port RS-232/RS-422/RS-485 mode selection for COM4 (IO board) Mode Selection Pin Setting RS-232 RS-422 RS-485 (Default) SW1 ~ SW5 - 18 - ERC-1005...
  • Page 25: Operation Control

    The PC will be rebooted (cold reset). 4.6 Status Indicator Display Meaning Description Disconnected from power supply POWER Indicates PC status Green PC is operating No access Indicates HDD access Yellow Accessing ERC-1005 - 19 -...
  • Page 26: Assembly And Maintenance

    Assembly and Maintenance 5. Assembly and Maintenance 5.1 Overall Assembly Drawing Item Description Item Description Upper cover Chassis Bottom cover Expansion board Motherboard - 20 - ERC-1005...
  • Page 27: Installing The Cover

    3、 When the board is properly in position, tighten the two captive screws on both sides of the motherboard panel; 4、 Install the expansion card in the same way. ERC-1005 - 21 -...
  • Page 28: Removing The Motherboard

    2、 Remove the four screws fixing the hard disk bracket as shown in the figure; 3、 Gently remove the hard disk module away from the SATA connector on motherboard to take the module out. - 22 - ERC-1005...
  • Page 29: Installing The Wall-Mounted Bar

    6、 Use three countersunk head screws of the corresponding specification to fix the guide rail for the left/right movable bracket with the movable tray; 7、 Fasten the captive screws on the left/right mounting bracket, so as to fix the mounting brackets with the movable bracket. ERC-1005 - 23 -...
  • Page 30: Installing The Drivers

    Installing the Drivers 6. Installing the Drivers Regarding the driver program of this product, please refer to the enclosed CD. - 24 - ERC-1005...
  • Page 31: Appendix

    Follow the power-on prompt and Incorrect time or press the key to enter the BIOS Incorrect BIOS setting date on PC Setup; adjust the time and date in BIOS Setup. ERC-1005 - 25 -...
  • Page 32 IO Poor contact of the slot card, unstable fixing or improper card can be used dust-proof measures; please when used again remove and install the card for a few times or use another slot. - 26 - ERC-1005...

Table of Contents