ICP H8MPT100J20A1 Installation Instructions Manual

Natural gas to propane and high altitude conversion kit

Advertisement

Quick Links

INSTALLATION
INSTRUCTIONS
For
Natural
Gas to Propane
and
High
Altitude
Conversion
Kit No: 1011789
This kit is designed to convert the NTP6, TNE, NDP6, TDE, NTPM, TNK, NCPM, TCK, NTVM,
VNK, *9MPV, *9MPT, *8MPV and *8MPT Series Furnaces
equipped
with Honeywell
SV9540
Series gas valves and Honeywell
Q3450 igniters from Natural Gas to Propane
Gas.
* Denotes Brand (T, H or C)
This conversion kit shall be installed by a qualified service agency.
Please
read these
instructions
completely
before attempting
installation.
Consult gas supplier and tables in National Fuel Gas
Code NFPA 54/ANSI Z223.1,1992 or latest edition. In Canada, the
National Standard CAN/CGA B149-1 and B149-2.
Parts List
Description
Part#
Qty
Burner Orifice #54
1011376
5
Pilot Orifice,
LP (0.011)
1009136
1
Honeywell
Cony. Kit #396021
1011828
1
Switch, Low Pressure
1008801
1
Fitting Asy.
1009775
1
Inlet Fitting
1147904
1
Wire Asy.
1009516
1
Label, Field Conversion
1009678
1
Label, LP Conversion
1011832
1
Label, Derate
2505235
1
Instructions
44106101507
1
Parts
for High
Altitude
Conversion
Burner
Orifice
#55 (2000'
- 7000')
Burner
Orifice
#56 (7000'
- 8000')
Orifices
required,
but not included
in kits.
1011354 as required
1011355 as required
This
conversion
kit
shall
be installed
by
a
qualified service technician
in accordance
with the
Manufacturer's
instructions
and
all applicable
codes and requirements
of the authority
having
jurisdiction.
The
qualified
service
agency
performing
this work assumes
responsibility
for
the proper conversion
of this furnace with this kit.
Failure to follow
these instructions
exactly
can
result
in death,
personal
injury
and/or
property
damage.
AVERTISSMENT
Cet ensemble
de conversion
ne doit etre installe
que par le representant
d'un organisme
qualifie
et
conformement
aux instructions
du fabricant
et
tous
les
codes
et
exigences
applicables
de
I'autorite
competente.
L'organisme
qualifie
quieffectue
les
travaux
est
responsable
de
la
conversion
correcte
de ce generateur
d'air
chaud
I'aide
de cet ensemble.
Quiconque
ne respecte
pas a la lettre
les instructions
darts
le present
manuel
risque
de declencher
un incendie
ou une
explosion
entrainant
des
dommages
materiels,
des
lesions
corporelles
ou
la
perte
de
vies
humaines.
General
Information
This
kit is for conversion
of furnaces
equipped
with
Honeywell
SV9540
Series
2-stage
gas valves
certified
for use with Natural
Gas (and so marked)
to units functionally
the same as the certified
furnace
for use with
Propane
Gas.
Before
the furnace
can be
operated
with LP Gas, the LP low pressure
must be installed
(90+
models
ONLY).
A gas valve conversion
kit must be installed
and
main burner
orifices
and pilot burner
orifice must be replaced
with
orifices
in this kit or with
properly
sized
orifices
for high altitude
ordered
separately.
The orifices
provided
in this kit are stamped
to indicate
the size
(twist drill number)
and are sized
for commercially
pure propane
gas ONLY.
Do NOT use them
with butane
or a mixture
of butane
and propane
gas,
or at elevations
above
2000'.
The parts
list
specifies
the size orifices
supplied
in the kit.
Compare
the size
marking
on the orifices
with the sizes
as listed
in the parts
list.
Make sure you have the correct
main
burner
orifices.
Extreme
care
is used to assure
that this kit contains
the proper
orifices.
Oversized
orifices
could
result
in
hazardous
conditions,
especially
if the venting
is inadequate.
For that
reason,
we recommend
that the installer
check
the size of the
orifice
with a new twist drill of the correct
size.
This procedure
assures
that the orifices
provided
are the correct
size.
D
Shut
off gas supply
to furnace
at manual
shut-off
valve
before
starting
installation.
D
Disconnect
electric
power
supply
to the furnace
before
starting
installation.
D
Check
for gas
leaks
after
installation
of kit and
before
attempting
to start furnace.
D
Locate
the LP Gas Conversion
Label
next to the furnace
rating
plate.
D
Fill out and attach
the Field Conversion
Label to the front
exterior
of the furnace.
Gas Pressure
D
Refer to the furnace
rating
plate for the approved
gas input
ratings.
D
Gas input
to burners
MUST
NOT exceed
the rated input
shown
on rating
plate.
D
Do
NOT
allow
minimum
gas
supply
pressure
to vary
downward.
Doing so will decrease
input to furnace.
Refer
to Table
1 for gas supply
and manifold
pressures.
441 06 1015 07 (10/2003)

Advertisement

loading

Summary of Contents for ICP H8MPT100J20A1

  • Page 1 INSTALLATION INSTRUCTIONS Natural Gas to Propane High Altitude Conversion Kit No: 1011789 This kit is designed to convert the NTP6, TNE, NDP6, TDE, NTPM, TNK, NCPM, TCK, NTVM, VNK, *9MPV, *9MPT, *8MPV and *8MPT Series Furnaces equipped with Honeywell SV9540 Series gas valves and Honeywell Q3450 igniters from Natural Gas to Propane Gas.
  • Page 2: Installation

    Table 1 Gas Pressures Disassembly Supply Pressure Manifold NTPM/TNK Pressure NCPM/TCK Type Recommended Max. Min. Hi Fire Lo Fire NTVM/VNK Nat. 7" 14" 4.5" 3.5" 1.7" (1.7kPa) (3.5kPa) (1.1kPa) (0.9kPa) (0.5kPa) 11" 14" 11" 10" 4.9" (2.7kPa) (3.5kPa) (2.7kPa) (2.5kPa) (1.3kPa) Important Notes...
  • Page 3 High Altitude Installation These units may be installed at full input rating when installed CarbonMonoxidehazard. altitudes up to 2000'. The #54 burner orifices supplied in this kit are NOxinserts for use with NaturalGas units sized for commercially pure propane gas only, for use between ONLY.
  • Page 4 Typical Honeywell Changing Pilot Orifice Regulator Assembly Natural BLACK WHITE Orifice with Red Dot 25-22-17 Gas Valve Conversion Conversion of Honeywell SV9540 & SV9541 Gas Valves using Natural Gas Conversion Kit #396021. 25-22-56 Remove the two screws securing the Hi/Lo regulator cover to the valve.
  • Page 5 Typical Gas Piping and Adding LP Low Pressure Switch (Required for 90+ and recommended for 80+) High Fire Shutoff valve Pressure Switch Low Fire Fire Lr%Wssure_ Switch Typical left Switch side gas pipe entry. J \_' Wires from kP Low Pressure Switch BL-- Disconnect...
  • Page 6 Reassembly Main Burner Reassemble all parts in reverse order as removed except leave burner compartment cover off (90+ONLY) until after Burner Face manifold pressure has been adjusted. Attach LP Conversion Label Burner Orifice Ring to the front exterior of the furnace, Manifold Assembly - Be sure to engage...
  • Page 7: Verify System Operation

    Pilot Burner Flame Check High Alitude Derate Label Pilot flame should envelope end of the igniter sensor 3/8" to 1/2". The derate label supplied with the orifice kit must be completed and affixed to the furnace near the rating plate. Fill in the manifold pressure, orifice size and revised...

This manual is also suitable for:

H9mpt050f12b1H8mpt075f14a1H8mpv125j20a1H8mpt100f14a1H8mpt125j20a1H8mpv075f14a1 ... Show all