Pax3 series package air conditioners

Advertisement

Installation Instructions
PAX3 Series
PACKAGE AIR CONDITIONERS
TABLEOF CONTENTS
UNITDIMENSIONS ......................................
2 - 3
SAFEINSTALLATIONREQUIREMENTS .........................
4
LOCATING THE UNIT .......................................
4
CLEARANCES ............................................
4
INSTALLATION............................................
5
GROUNDLEVELINSTALLATION ..............................
5
RooftopINSTALLATION.....................................
5
HOISTING................................................
5
DOWNFLOWCONVERSION ..................................
5
CONDENSATEDRAIN.......................................
5
ELECTRICALWIRING ...................................
6
DUCTWORK ..........................................
7
FILTERS .............................................
7
AIRFLOWAD,JUSTMENT ................................
8
START-UPPROCEDURES ...............................
8
Sequenceof OPERATION................................
9
MAINTENANCE .......................................
9
RIGGING ...........................................
12
WIRING DIAGRAMS ...................................
13
C@US
LISTED
519 01 1301 O0
1-4-06
Printed in U.S.A.
Key: PAX3

Advertisement

Table of Contents
loading

Summary of Contents for ICP PAX336000K00A1

  • Page 1: Table Of Contents

    Installation Instructions PAX3 Series PACKAGE AIR CONDITIONERS TABLEOF CONTENTS UNITDIMENSIONS ........2 - 3 ELECTRICALWIRING ........SAFEINSTALLATIONREQUIREMENTS ......DUCTWORK .......... LOCATING THE UNIT ........FILTERS ..........CLEARANCES ..........AIRFLOWAD,JUSTMENT ........ INSTALLATION..........START-UPPROCEDURES ....... GROUNDLEVELINSTALLATION ......Sequenceof OPERATION........ RooftopINSTALLATION........MAINTENANCE ........HOISTING..........
  • Page 2: Unitdimensions

    "B" CHASSIS UNIT DIMENSIONS 1. Unit Dimensions Units in "B" Chassis Configuration PACKAGE AIR CONDI- PAX324 - 36 TIONER UNITS "B" Chassis (473/8 x473/8) _"B" DIM. 32-1/2 _ _,_,_-_"_._"_. 47-3/8 I 1203 _f(_d(_4C_b_%_ _ 47-3/8 1203 _ _N_.._.___._) "_ 3-1/8 I _"...
  • Page 3 "C" CHASSIS UNIT DIMENSIONS ECTRICAL POWER CONDUIT ('K" DIM.) VOLTAGE (12.7) CONDUIT PACKAGE AIR CONDITION- ER UNITS "C" Chassis (473/8 x 73) INCHES MILLOMETER8 47-3/8 1203 1354 4-5/8 18-3/4 18-3/4 1 &1-1/4 25&31 4-1/4 5-1/4 12-1/4 12-1/4 ,,p,, 16-7/8 UNIT BAEE SHOWN EEPARATELY_...
  • Page 4: Safeinstallationrequirements

    2. SAFE INSTALLATION REQUIREMENTS FIRE, AND ELECTRICAL SHOCK HAZARD Installation and servicing of air-conditioning equipment can be hazardous due to system pressure and electrical Failure to carefully read and follow all instructions in this components. Only trained and qualified personnel should manual could result in furnace malfunction,...
  • Page 5: Installation

    Do NOT install the unit in a location that will permit - Platform must be high enough to allow for proper discharged air from the condenser to recirculate to the condensate trap installation and drainage. See Figure 2 and associated text for more information about condenser inlet.
  • Page 6: Electricalwiring

    supplied condensate trap that will allow a standing column of water of at least 2" (50.8mm) MUST be installed. Top of outlet from trap MUST be at least 1" (25.4mm) below top of REDUCED EQUIPMENT LIFE HAZARD outlet from unit. Install the trap as near to the unit as Failure to follow these precautions...
  • Page 7: Ductwork

    (Qty x w x d) (sq inches) PAX324000K00A1 1 x 20"x 20" 1 x l0"x20" PAX330000K00A1 1 x 20"x 24" 1 x 12"x 20" PAX336000K00A1 2 x15"x 20" 1 x15"x20" PAX342000K00A1 2 x18"x 20" 1 x18"x20" PAX348000K00A1 2 x 20"x 20"...
  • Page 8: Airflowad,Justment

    6. AIRFLOW ADJUSTMENT CIRCULATING AIR BLOWER SPEEDS BLOWERPERFORMANCEDATA ModelNumber PAX324 PAX330 PAX336 9AX342 PAX340 PAX360 Torque(oxFt} 5.96 1096 15.53 18.04 2902 11.92 13.02 1004 23.06 29.02 1059 24.00 34.35 5294 1906 23.0E 34.12 4180 4400 26.98 32.00 5114 59.92 80.00 3012 3106 55.84 7310 8000 Speed Tap /25/ //06...
  • Page 9: Sequenceof Operation

    9. MAINTENANCE Check the unit's operation as outlined in the following instructions. If any unusual sparking, odors or unusual noises encountered, shut electric power MONTHLY MAINTENANCE AND INSPECTION immediately. Recheck for wiring errors, or obstructions in or CHECKS near blower motors. Air Filters 1.
  • Page 10 Motor removal and replacement 3, Disconnect all wires from housing and slide housing out of unit. Reverse this process to reinstall. This method is required to replace or repair blower wheel, Circulating Air Blower blower housing, or any unreachable components behind blower assembly.
  • Page 11 Control Box FIGURE Transformer Motor Board Control Plate Contactor Run Capacitor Capacitor Strap...
  • Page 12: Rigging

    R GG NG INSTRUCTION rA_L_uRE -to fOLLOW THESE _NS-rRUC-r,ONS WARNNG RESULT IN PROPERTY DAMAGE, BODILY INdURY OR DEATH. - ALL PANELS MUST IN PLACE WHEN RIGGING LIFTING. - HOOK RIGGING SHACKLES THROUGH HOLES IN BASE RAIL, SHOWN IN DETAIL-A. - USE SPREADER BARS, WHEN...
  • Page 13: Wiring Diagrams

    10. Wiring Diagrams 2 to 5 Ton Wiring Diagram FI£L_ ¥2 ,OMPOBEHT ARfi£i_G{MENT SEBTTO_ S_C ION S CT]rOi 1131...

Table of Contents