Technical Specifications

Unit Environment and Operating
Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is
operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-
circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign
matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the enclosure,
and the same operating guidelines listed above will still apply.
Temperature Range
Relative Humidity
Maximum Altitude (unpressurized)
* Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained sunlight.
Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.
Power Supply
Operating Voltage Range
Rated Voltage Range
Rated Line Frequency
Operating Line Frequency Range
Rated Input Current
Heat Dissipation
Power Supply Fan
ENERGY STAR Compliant
FEMP Standby Power Compliant
(<2W in S5 – Power
Off)**
Microtower
Non-operating: 5% to 95% (non-condensing at ambient)
Microtower
300-watt BTX power
supply – Passive PFC
115v/230v line switch
90 to 132VAC, or 180 to
264VAC
100 to 127VAC, or 200
to 240VAC
50/60 Hz
47–63 Hz
8A/4A
Typical 315 btu/hr
(79 kg-cal/hr)
Maximum 1575 btu/hr
(397 kg-cal/hr)
Variable speed fan
X
DA - 12863 North America — Version 27 — October 28, 2009
Operating: 50° to 95° F (10° to 35°
Non-operating: -22° to 140° F(-30° to 60° C)
Operating: 10% to 90% (non-condensing at ambient)
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
300-watt 85%
240-watt BTX power
efficient*
BTX power
supply – Active PFC
supply – Active PFC
115v/230v line switch
90 to 264VAC
90 to 132VAC, or 180 to
100 to 240VAC
100 to 127VAC, or 200
50/60 Hz
47–63 Hz
5A/2.5A
Typical 270 btu/hr
Typical 315 btu/hr
(68 kg-cal/hr)
Maximum 1280 btu/hr
(322 kg-cal/hr)
Variable speed fan
Variable speed fan
X
X
HP Compaq dc5800 Business PC
Small Form Factor
C)*
Small Form Factor
240-watt 85%
efficient* BTX power
supply – Active PFC
90 to 264VAC
264VAC
100 to 240VAC
to 240VAC
50/60 Hz
47–63 Hz
6A/3A
3.5A/1.75
Typical 270 btu/hr
(79 kg-cal/hr)
(68 kg-cal/hr)
Maximum
Maximum 1025 btu/hr
1260 btu/hr
(258 kg-cal/hr)
(317 kg-cal/hr)
Variable speed fan
X
50/60 Hz
47–63 Hz
X
X