Display Mode Information - La Crosse Technology Battery Charger Instruction Manual

Hide thumbs Also See for Battery Charger:
Table of Contents

Advertisement

seconds to activate the mode change. The subsequent pressing of the mode key will enable
to toggle between the "Charge", "Discharge", "Test" and "Refresh" mode.)
Note:
After selecting the Test mode, user may select a different charging current in the Test
mode by pressing the CURRENT key, within 8 seconds after the batteries are
inserted. The afterward-discharging current will be half of the selected charging
current (see Table 3).
Table 3. TEST MODE Current
User-selected Charging
current
Thereafter Discharging
current

DISPLAY MODE INFORMATION

User can use different display modes to monitor the rechargeable battery condition during
the different operations (see below figure and Table 4 to 7).
Different display modes are exhibited: Charging
current, Time, Voltage and Capacity
The Charging
current in
(mA)
Test mode
200 mA
500 mA
700 mA
100 mA
250 mA
350 mA
17
Different operating modes
19
The maximum charging current is 700 mA.
After the test mode is finished, the display will shift between the "Full" sign and the
battery capacity (in mAh or Ah) automatically in 3-second intervals until the
rechargeable batteries are removed. User can switch to other displays by pressing the
DISPLAY key.
TRICKLE CHARGING
After the rechargeable battery is fully charged in any of the operating modes, the charger will
give a small amount of current to the rechargeable batteries to maintain the fully charged
level. This mode is automatically launched after rechargeable batteries are fully charged and
kept at the charging unit. The signal "Full" will be displayed on the LCD.
Table 4. Various displays in Charge Mode
Various displays (toggled by pressing DISPLAY key)
Stage in Charge
mode
Voltage (V)
Current (mA)
During charging
Charging current
Instantaneous
Battery voltage
Full stage
Trickle charging
Table 5. Various displays in Discharge Mode
Various displays (toggled by pressing DISPLAY key)
Stage in
Discharge mode
Voltage (V)
Current (mA)
During
discharging
Instantaneous
During charging
Battery voltage
Charging current
Trickle charging
Full stage
Battery capacity displayed in
(mAh) as the checking is
finished in Test mode.
18
Capacity
*Time (hh:mm)
(mAh/ Ah)
Charging time
Accumulated
elapsed
capacity
current
Capacity
*Time (hh:mm)
(mAh/ Ah)
Discharging
Discharging time
Capacity during
current
elapsed
discharging
Charging time
Accumulated
elapsed
capacity
current
20