11. Installing The Appliance

Note: READ THIS SECTION FULLY BEFORE COMMENCING THE
INSTALLATION
11.1 Unpacking
Check the contents against the packing list.
Remove
the
wall
mounting
manifold/mounting plate assembly.
11.2 Site Preparation
Check that the correct position for the appliance has been
chosen and that the wall is sound, flat and will support the
weight of the appliance. Refer to Sections 4 & 5 and Tables 4
and 8.
11.3 Fixing Holes and Flue Opening
If it is necessary for any of the pipes to run up the back of the
appliance then the, optional extra, space frame must be fitted to
the wall.
Hold the template to the wall. Check that the template is level.
Mark the position of the fixing holes and the flue opening. Refer
to Fig 15.
Drill the fixing holes 60mm deep for the No. 12 size plugs.
Fig. 15 . Fixing the wall mounting plate.
Fig. 16 .Mounting plate manifold.
1.
O-Ring
2.
Locating pegs
3.
Pre-plumbing
manifold
* With optional diverter
valve only
template
and
the
116
723
Pre-plumbing
manifold
99
Dimensions in mm
1
Cut the flue duct hole at 110mm diameter [150mm diameter for
internally fitted flues].
11.4 Wall Mounting Plate and Manifold
Fit the plugs and fix the mounting plate and manifold assembly
to the wall. Refer to Fig 15.
11.5 Gas and Water Pipes
Fix the appropriate fitting to the gas cock to connect the inlet
supply pipe. Refer Fig 16.
It is important that the system pipes are not fixed near the
appliance using clips that put a strain on the connections.
Before the appliance is connected to the wall manifold
thoroughly flush the system.
11.6 Install the Boiler
Lift off the cabinet front panel.
Check that the gas and water valves on the manifold are closed.
Refer to Fig 16.
Remove the plastic cover and fit the seals to the service valves
on the manifold. Refer to Fig 16.
211
Top wall fixing screws
(2)
820
Plumbing manifold
fixing screws
(4)
425
2
3
13
(230mm if the optional
space frame is fitted)

Hide quick links: