Download Print this page

Kenmore 41744131000 Installation Instructions Manual page 4

Elite front load washer

Advertisement

Available languages

Available languages

Installation
Requirements
Electrical system requirements
CIRCUIT - Individual,
properly
polarized
and grounded
15
amp. branch
circuit fused with 15 amp. time delay fuse
or circuit
breaker.
POWER SUPPLY - 2 wire, with ground, !20 volt single
phase, 60 Hz, Alternating
Current.
Because of potentially
inconsistent
voltage
capabilities,
the
use
of this washer with power created
by gas
powered
generators,
solar powered
generators,
wind
powered
generators
or any other generator
other than
the local utility company
is not recommended.
OUTLET RECEPTACLE - Properly
grounded
3-prong
receptacle
to be located
so the power supply cord is
accessible
when the washer is in an installed
position.
G
wal
Do not, under
any circumstances,
cut, remove,
or bypass the
grounding prong.
Power cord with
3-prong grounded plug
...... N oTE ........
GFI (Ground
Fault Interrupter)receptacle
is not required.
Ground requirements
ELECTRICAL SHOCK HAZARD
Improper
connection
of the equipment
grounding
conductor
can result in a risk of electrical
shock. Check
with a licensed electrician
if you are in doubt as to
.... whether
the appliance
is proper!y
grounded. ...................................................................................
The washer MUST be grounded.
In the event of
malfunction
or breakdown,
grounding
will reduce the
risk of electrical
shock by providing
a path of least
resistance
for electrical
current.
Since your washer is equipped
with a power supply
cord having
an equipment-grounding
conductor
and a grounding
plug, the plug MUST be plugged
into an appropriate,
copper
wired receptacle
that is
properly
installed
and grounded
in accordance
with
all local codes and ordinances
or in the absence
of local codes, with the National
Electrical
Codes,
ANSI/NFPA
70 (latest edition).
If in doubt, caii
a licensed electrician.
DO NOT cut off or alter
the grounding
prong on the power supply cord. In
situations
where a two-slot
receptacle
is present,
it is the owner's responsibility
to have a licensed
electrician
replace
it with a properly
grounded
three
prong grounding
type receptacle.
Water supply requirements
Hot and cold water
faucets MUST be installed
within 42
inches (107 cm) of your washer's water
inlet. The faucets
MUST be 3/4 inch (1.9 cm) and have threading
for laundry
hose connection.
Water
pressure MUST be between
30
and 120 psi. Pressure difference
between
hot and cold
cannot be more than 10 psi. Your water
department
can
advise you of your water
pressure.
Drain system requirements
1
Drain capable
of eliminating
17 gals (64.3 L) per
minute.
2
A standpipe
diameter
of 1-1/4 in. (3.18 cm)
minimum.
3
The standpipe
height above the floor should be:
Minimum
height:
24 in. (61 cm)
Maximum
height:
96 in. (244 cm)
1
96"
(244cm)
[lrlax.
H
24"
(61cm)
rain.
4
Drain hose attached
to the washer can reach a 74 in.
(188 cm) high standpipe.
For higher standpipe,
use hose
P/N 137098000,
available
from Sears Parts & Repair.
Coil ]-800-4-MY-HOME