Setting Parameters Of The Setup Software - Panasonic BM-ET300 Setup Manual

Iris camera
Table of Contents

Advertisement

3. Edit the parameters.
Refer to "Setting Parameters of the Setup Software" for
each parameter. (Refer to "Setting Parameters of the
Setup Software".)
4. Click "Store". Or select " Connection (C) " – " Store
(S)" in the menu bar.
The changed parameters will be written into the iris
camera, and the message window "Store this setting?"
will appear. Check the setting and click on "OK". After
the
parameter
writing,
"Completed." will appear. Then, click on "OK".
5. Click on "Close" to quit the setup software.
n Power Supply Shut Down and Setup Cable
Removal
Shut down the power supply, and remove the cable from
the iris camera.
m Setup Switch Setting for Normal Operation
Move Setup Switch 1 to ON to set the iris camera the "nor-
mal operation" mode. (Set all the other switches to OFF.)
ON (Upper side)
1 2 3 4
Note: The wrong switch setting may prevent the iris camera
from booting properly.
, Attaching the Front Cover
Attach the front cover to the iris camera.
the
message
window
■ Setting Parameters of the Setup
Software
Notes:
• Items displayed in red and marked with ✽ can be con-
figured only by the setup software. They cannot be con-
figured in the administration software.
• If there is a parameter difference between the setup
software and administration software, the latter has pri-
ority.
● Menu Bar
• File (F)
Open (O): The setup file, saved by clicking "Save (S)",
is opened. (Only files saved by clicking "Save (S)"
can be opened.)
Save (S): The setting is saved into a setup file.
Note: Do not change the file extension (Setup data
(*.dat)).
• Connection (C)
COM Port Connection (C): When you click on this
item, the "COM port Connection" window appears.
You can change the COM port (COM1 or COM2)
selected in the "BM-ET300 Login" window.