Installation - Thermador CVS2 Installation Manual

Downdraft
Hide thumbs Also See for CVS2:
Table of Contents

Advertisement

INSTALLATION
WITH OTHER
COOKTOPS
WHERE
SPECIFIED
(SEE PART B)
21/4"
Figure 8
B. FOR INSTALLATION
WITH ANOTHER
BRAND OF COOKTOP
(Figure 8)
Have the following cooktop measurements available before
proceeding All cooktop dimensions should be verified
through measurement prior to cutting the countertop:
CCW = Cooktop Cutout Width
CCD = Cooktop Cutout Depth
COW = Cooktop Overall Width
COD = Cooktop Overall Depth
with the above dimensions confirmed, determine the cutout
size as follows:
1.
Find the cutout width,
(CW):
If CCW is smaller than the CVS2 / UCV2 cutout width
then:
Installation
CW
CVS230 / UCV230
283/8
CVS236 / UCV236
343/8
CVS245 / UCV245
433/8
If CCW is larger than the CVS2 / UCV2 cutout width
then:
CW = CCW
See Figure 8 for CVS2 / UCV2 cutout widths and
dimension definitions,
2.
Calculate
the cutout depth, CD:
Determine the cooktop overhang (CO)
CO = (COD-CCD)/2 (Assumes front and rear cooktop
overhangs are equal) Calculate the cutout depth, (CD):
CD = COD-CO+1-7/8"
3.
Determine
setback
(SB) distance
from front of
countertop
to front of cutout.
SB is specified in the
installation instructions shipped with the cooktop,
4.
Backsplash
thickness
must not exceed BT as
calculated
below:
BT = 24 7/8"
-
OD-SB+CO
(Provides 1/8"clearance between vent and backsplash.)
A negative value for BT means countertop is too small
for the installation,
5,
Verify that the available flat countertop has a width
greater than OW and a depth greater than OD,
OW depends on the installation:
CVS230 / UCV230:
OW equals the greater of
COW or 30",
CVS236 / UCV236:
OW equals the greater of
COW or 36",
CVS245 / UCV245:
OW equals the greater of
COW or45".
OD is determined by: OD=COD+21/8 ",
6.
Cut countertop
using dims: CD, CW and SB as
defined in Figure 8,
Page 8