Thermador CVS30R Installation Instructions Manual

Thermador CVS30R Installation Instructions Manual

Universal cook’n’vent rating: 120 volt, 60 hz.,10.2 amps
Hide thumbs Also See for CVS30R:

Advertisement

For Integral Blower Installations:
• Requires Integral Blower: Model # VTN600CVR
• Requires Discharge Duct Size 3
• Requires Power Supply • 120 Volt • 15-20 Amps., 3 prong receptacle • 60 Hz., AC.
• See Steps 3 and 5 for electrical receptacle and duct outlet location
For Remote Blower Installations:
• Requires Remote Blower: Model # VTR1000Q or VTR600R
• Requires Duct Transition: Model # CVD310 (for 3
-1
3
/
" x 14" duct)
4
• Requires 4 wires and 1 ground wire connecting blower and vent
• Requires Power Supply • 120 Volt • 15-20 Amps., 3 prong receptacle • 60 Hz., AC.
• Requires 10" round ducting to connect to VTR1000Q Remote Blower or 8" round
for VTR600R
• See Steps 3 and 5 for electrical receptacle and duct outlet location
INSTALLATION MUST COMPLY WITH ALL APPLICABLE CODES.
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
IMPORTANT: Save these instructions for the local electrical inspector's use.
INSTALLER: Please leave these Installation Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
SAFETY WARNING: Disconnect power by removing plug from receptacle before installing or
WARNING - TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
CAUTION: THIS PRODUCT IS INTENDED FOR
GENERAL VENTILATING USE ONLY. DO NOT
USE TO EXHAUST HAZARDOUS OR
EXPLOSIVE MATERIALS OR VAPORS.
A.
Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
B.
Before installing, servicing or cleaning the unit, dis-
connect power cord.
C
Installation work and electrical wiring must be done
by qualified person(s) in accordance with all appli-
cable codes & standards, including fire-rated con-
struction.
D.
Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
READ AND SAVE THESE INSTRUCTIONS
-1
/
" x 10"
4
servicing this unit.

SAFETY INSTRUCTIONS

UNIVERSAL COOK'N'VENT
INSTALLATION INSTRUCTIONS
MODELS: CVS30R • CVS36R • CVS45R
Rating: 120 Volt, 60 Hz.,10.2 Amps.
-1
/
" x 10" duct) or CVD314 (for
4
burning equipment to prevent backdrafting. Follow
the heating equipment manufacturers guideline and
safety standards such as those published by the Na-
tional Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local
code authorities.
E.
When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
F.
Caution — To reduce risk of fire and to properly
exhaust air, be sure to duct air outside. Do not vent
exhaust air into spaces within walls, ceilings, attics,
crawl spaces or garages.
G.
WARNING - USE ONLY METAL DUCT WORK.
H.
Install this ventilator in accordance with all require-
ments specified by the manufacturer of your cooktop.
I.
DO NOT USE THIS VENT WITH ANY SOLID-
STATE SPEED CONTROL DEVICE.
®
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Thermador CVS30R

  • Page 1: Safety Instructions

    ® UNIVERSAL COOK’N’VENT INSTALLATION INSTRUCTIONS MODELS: CVS30R • CVS36R • CVS45R Rating: 120 Volt, 60 Hz.,10.2 Amps. For Integral Blower Installations: • Requires Integral Blower: Model # VTN600CVR • Requires Discharge Duct Size 3 " x 10" • Requires Power Supply • 120 Volt • 15-20 Amps., 3 prong receptacle • 60 Hz., AC.
  • Page 2: Plan The Installation

    It is intended for use with Provide "make-up air" to installation location to im- any residential 30-inch, 36-inch or 45-inch model (Thermador prove performance and prevent problems, such as or other) gas or electric cooktop. It is not intended to be fireplace chimney downdrafts.
  • Page 3 1/8" Min. Figure 2 2-3/8" • Be certain to avoid interferance with gas and electric supply to 1/4" cooktop. • Shelving and drawer depths are dependent upon cooktop Cooktop depth and setback. 1-3/4" 3-1/16" 2-1/16" 25" Cutout SB (See Depth Fig.
  • Page 4 FIGURES 3 THROUGH 6 ARE EXAMPLES OF POSSIBLE DUCTING Figure 3 Figure 4 INTEGRAL BLOWER REMOTE BLOWER Remote Blower Duct Attach- ment Box CVD310 or CVD314 VTN600CVR Wall Cap 1255-1 12" Min. Ground ROOF MOUNT INSTALLATION THROUGH WALL INSTALLATION Figure 5 Figure 6 INTEGRAL BLOWER REMOTE BLOWER...
  • Page 5 TOTAL (of both columns) = NOTE: Fittings with model numbers stated are available through your MUST be LESS than: Thermador dealer. All other fittings are available from most major Integral Blower- 85 ft. hardware stores. Remote Blower- 70 ft. Page 5...
  • Page 6: Duct Work Installation Guidelines

    (FIGURE 7 AND TABLE 3) For installation of the Cook'n'Vent ® with a Thermador Provide an opening in the countertop as specified in cooktop, refer to Part A and Figure 7. For installation with Table 3. Make sure the distance from the front of the another brand of cooktop, refer to Part B and Figure 8.
  • Page 7 TABLE 3 (in inches) CVS30R/ 36R/ 45R INSTALLATION DIMENSIONS WITH THERMADOR COOKTOPS Cooktop BT, Max++ Model No. Cutout Cutout Overall Overall Minimum Backsplash Width Depth Width Depth Set Back Thickness 30” Cooktops: Installed with CVS30R SGC304* 28-5/8 21-15/16 21/32 SGCS304*...
  • Page 8 Figure 8 INSTALLATION WITH OTHER COOKTOPS WHERE SPECIFIED (SEE PART B) INSTALLATION WITH ANOTHER BRAND OF COOKTOP (Figure 8) The installer will need to have the cooktop installation Calculate the cutout depth, CD: instructions available to complete the installation. All Determine the cooktop overhang (CO) cooktop dimensions should be verified through measure- CO = (COD-CCD)/2 (Assumes front and rear cooktop...
  • Page 9: Prepare Duct Cutouts In Cabinet

    A-A & B-B Receptacle 30" Location Adjustable Within Range Note: Centerlines of Cabinet Bottom Shelf Rectangular Duct Shown CABINET CUT-OUT FOR DUCTWORK TABLE 4 INTERNAL BLOWER VTN600CVR CVS30R 8-3/8 9-5/8 26-3/4 17-9/16 CVS36R 8-3/8 3-7/8 13-3/16 26-3/4 17-9/16 CVS45R...
  • Page 10: Install Ductwork

    STEP 4 STEP 6 INSTALL DUCTWORK MOUNT VENT & COOKTOP (REMOTE BLOWER - if used) Remove grease filters and any packing materials from Install the ductwork and remote blower (if used) in inside the intake. accordance with the ductwork routing plan developed Set the vent intake into rear of countertop opening.
  • Page 11 STEP 7 Figure 11 Vent MOUNT INTEGRAL Power BLOWER OR Cord Remote Blower Duct Transition Transition Electrical Connection Box (J-Box) "Clean-out" (See Fig. 11) Area Flanged Edge Integral Blower VTN600 CVD310 Access Only Vent Intake Panel A. Place blower in front of intake CVD314 Flanged Edge on bottom of cabinet, take...
  • Page 12 Manual for additional information or call Thermador blower will immediately turn off. Customer Support 1-800-735-4328. 5551 McFadden Avenue, Huntington Beach CA, 92649 • 800-735-4328 ECO71510 • 19-12-201D • © 1996 Thermador Corporation • Litho in U. S. A. 3/99 Page 12...

This manual is also suitable for:

Cvs36rCvs45r

Table of Contents