Venting Kits; Install Vent System - Whirlpool WED5500BW0 Installation Instructions Manual

27" electric dryer
Table of Contents

Advertisement

Venting
Kits
For more information, call 1-800-901-2042,
or visit us at
www.appiianceaccessories.com,
in Canada, call
1-800-807-6777
or visit us at www.whirlpoo[parts.ca.
Part Number
Descriptions
8171587RP
0-5" Metal vent periscope
4396037RP
0"-18" Metal vent periscope
4396011 RP
18" - 29" Metal vent periscope
4396014
29" - 50" Metal vent periscope
4392892
In-Wall metal DuraVent
TM
Periscope
279818
4-way vent kit - white
W10186596
4-way vent kit - universal grey
4396028
Sure Connect
TM
venting kit
(over-the-top
installation)
4396009RP
5' Universal connect vent, flexible dryer venting
4396010RP
6' SecureConnect
TM
vent, flexible dryer venting
4396013RB
Dryer vent installer's kit
4396033RP
5' flexible dryer venting with clamps
4396727RP
8' flexible dryer venting with clamps
4396004
Dryer offset elbow
4396005
Wall offset elbow
4396006RW
DuraSafe
TM
close elbow
4396007RW
Through-the-wall
vent cap
4396008RP
4" steel dryer venting clamps - 2 pack
8212662
Flush mounting Iouvered vent hood 4"
Special
provisions
for mobile
home
installations:
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
----4
Determine vent path:
[]
Select route that will provide straightest and most direct
path outdoors.
[]
Plan installation to use fewest number of elbows and turns.
[]
When using elbows or making turns, allow as much room
as possible.
[]
Bend vent gradually to avoid kinking.
[]
Use as few 90 ° turns as possible.
Determine vent length and elbows
needed for best
drying performance:
[] Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified
in Vent system chart. Exhaust systems longer than those
specified will:
[]
Shorten life of dryer.
[]
Reduce performance,
resulting in longer drying times
and increased energy usage.
The Vent System Chart provides venting requirements that
will help achieve best drying performance.
Vent System
Chart
Number
of
Type
Box/Iouvered
Angled
90 ° turns
of vent
hoods
hoods
or elbows
Rigid metal
64 ft. (20 m)
58 ft. (17.7 m)
Rigid metal
54 ft. (16.5 m)
48 ft. (14.6 m)
Rigid metal
44 ft. (13.4 m)
38 ft. (11.6 m)
3
Rigid metal
35 ft. (10.7 m)
29 ft. (8.8 m)
4
Rigid metal
27 ft. (8.2 m)
21 ft. (6.4 m)
NOTE: Side and bottom exhaust installations have a 90 ° turn
inside the dryer. To determine maximum exhaust length, add
one 90 ° turn to the chart.
Install
Vent System
J.
Install exhaust
hood
rain.
12" rain.
(305 ram)
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
14