PRODUCT MODEL NUMBERS
LEV4634P
WED5590S
Electrical: A 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC
only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply,
if specified on the serial/rating plate) on a separate 30-amp circuit,
fused on both sides of the line is required. A time-delay fuse or
circuit breaker is recommended. Connect to an individual branch
circuit. Do not have a fuse in the neutral or grounding circuit.
Exhaust venting: Exhaust your dryer to the outside. Four-inch
diameter vent is required. Rigid or flexible metal exhaust vent must
be used. Do not use plastic or metal foil vent. Exhaust outlet hood
must be at least 12 inches from the ground or any object that may
be in the path of the exhaust.
RECESSED AREA AND CLOSET INSTALLATION
For closet installation, with a door, the minimum ventilation openings
in the top and bottom of the door are required. Louvered doors with
equivalent air ventilation openings are acceptable.
18"
(45.7 cm)
1"
1"
29"
1"
(73.66 cm)
(2.5 cm)
(2.5 cm)
(2.5 cm)
A
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
EXHAUST VENTING
Number of 90º
Rigid metal vent
turns or elbows
0
120 ft (36.6 m)
1
110 ft (33.5 m)
2
100 ft (30.5 m)
3
90 ft (27.4 m)
4
80 ft (24.4 m)
5
70 ft (21.3 m)
NOTE: Side and bottom exhaust installations have a 90° turn inside the dryer.
To deetermine maximum exhaust length, add one 90° turn to the chart.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Front Loading Electric Dryer
14" max.
2
48 in.
(35.6cm)
2
(310 cm )
2
24 in.
2
(155 cm )
27¾"
5½"
(70.5 cm)
(14 cm)
B
C
Flexible metal vent
40 ft (12.2 m)
37 ft (11.3 m)
33 ft (10.1 m)
30 ft (9.1 m)
27 ft (8.2 m)
23 ft (7.0 m)
OVERALL DIMENSIONS
43³⁄₈"
(110cm)
*26"
(66cm)
43³⁄₈"
(110cm)
*27¾"
(70.5cm)
3"
(7.6 cm)
3"
(7.6 cm)
* Most installations require a minimum 5 " (14 cm)
clearance behind the dryer for the exhaust vent with elbow.
See Installations Instructions, "Venting Requirements."
Recommended hood styles
A
4"
(10.2 cm)
A. Louvered hood style
B. Box hood style
Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns. Avoid making
90° turns.
Do not use vent runs longer than specified in vent length chart.
Determine the number of elbows you will need.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
15¼"
(38.74cm) 43³⁄₈"
(110cm)
*27¾"
(70.5cm)
29"
(73.66cm)
A
22¾"
(57.8cm)
43³⁄₈"
(110cm)
*27¾"
(70.5cm)
29"
(73.66cm)
C
A. Small opening side-swing door
B. Large opening side-swing door
C. Wide opening side-swing door
D. Wide opening hamper door
B
Acceptable hood style
4"
(10.2 cm)
4"
(10.2 cm)
22¾"
(57.8cm)
29"
(73.66cm)
B
13¾"
(34.9cm)
29"
(73.66cm)
D
2.5"
(6.4 cm)
Ref. 8577190
11-03-06