Location Requirements - Whirlpool WED7800XB0 Installation Instructions Manual

27" electric dryer
Table of Contents

Advertisement

Location Requirements
Explosion Hazard
Keep flammable
materials
and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (460 ram) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need
A location that allows proper exhaust installation.See "Venting
Requirements."
Aseparate 30-amp circuit.
If using a power supply cord, a grounded electrical outlet
within 2 ft (610 mm) of either side of dryer. See "Electrical
Requirements."
A sturdy floor to support total dryer weight of 200 Ibs. (90.7 kg).
Also consider combined weight of a companion appliance.
A level floor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended Dryer
Feet Kit, Part Number 279810. Clothes may not tumble properly
and automatic sensor cycles may not operate correctly if dryer is
not level.
For a garage installation, place dryer at least 18" (457 mm)
above floor. If using a pedestal, you will need 18" (457 mm) to
bottom of dryer.
Steam models only: Cold water faucets located within
4 ft. (1.2 m) of dryer, and water pressure of 20-100 psi
(137.9-689.6 kPa). Cold water supply may come from
washer using "Y" connector provided.
Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer may not shut off at the end of an
automatic sensor cycle, possibly resulting in longer drying times.
Do not install or store dryer where it will be exposed to water and/or
weather.
Check code requirements. Some codes limit, or do not permit,
installation of dryer in garages, closets, mobile homes, or sleeping
quarters. Contact your local building inspector.
Installation clearances
Location must be largeenough to allow dryer door to open fully.
Dryer Dimensions
431/2"
(1105 mini
221/4"
(565 ram)
NOTE: Most installations require minimum 5" (127 mm) clearance
for exhaust vent with elbow. See "Venting Requirements."
Installation
spacing for recessed
area or closet installation
The following spacing dimensions are recommended for this dryer.
Dryer has been tested for spacing of 0" (0 mm) clearance on sides
and rear. Consider recommended spacing for following reasons:
Consider additional spacing for ease of installation and service.
May need additional clearance for wall, door, and floor moldings.
Consider additional spacing on all sides of dryer to reduce noise
transfer.
For closet installation,with a door, minimum ventilation openings
in the top and bottom of the door are required. Equivalent
ventilation openings in Iouvered doors are acceptable.
Consider spacing for companion appliance.
Additional space required for rear exhaust of dryer to right or left.
__{
48" 2,
(310 c rn 2)
24" >
(155 c rn 2)
P_-5"
(127ram)
.z-a_n
4" ITlaX."
I
(25ram) (737ram)
(25ram)
1743ram)
Recessed
area
(76ram)
3
II_
Side view- closet
Closet door with
or confined area
vents
*Required spacing
Mobile home - Additional
installation
requirements
Dryer is suitable for mobile home installations. Installation must
conform to Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280 (formerly Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD Part 280) or Standard CAN/
CSA-Z240 MH.
Mobile home installations
require:
Metal exhaust system hardware, available for purchase from
your dealer.
Special provisions must be made in mobile homes to introduce
outside air into dryer. Openings (such as a nearby window)
should be at least twice as large as dryer exhaust opening.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wed7800xl0Wed7300xw0Wed7600xw0Wed7400xw0Wed7800xw0

Table of Contents