Cutout Dimensions/Requirements; Product Dimensions; Electrical Requirements - Whirlpool YGR556LRKB0 Installation Instructions Manual

30" (76.2 cm) electric refrigerated range
Hide thumbs Also See for YGR556LRKB0:
Table of Contents

Advertisement

Available languages

Available languages

Cutout dimensions/requirements
25" (63.5 cm) countertop depth and
24" (6! cm) base cabinet depth,
36" (91.4 cm) countertop height
I
.... jFor m,n,mum
I
-
_...... _
clearance to the
_'cm)
min.
top of the
_ning
width
/
_'Icooktop,
see
_
_..fJ
I_-
NOTE,*
1o6p,,45:p %
t
to countertop
.
30" (76.2 cm)
_--_
[
j°perfing
widih
"_'_
I
J
4" (!02 cm)
_'_
min. clearance from
both sides of range
to side wall or other
combustible
material
I _
J
I
b. j
I i
,%
receptical or
junction box-
/ 8" (20.3 cm) to
22" (55.9 cm) frorr
either cabinet,
7" (lZ8 cm) max.
from floor.
7/8" (2.2 cm) rain.
required between
cutout and cabinet
door or hinge.
* NOTE: 24" (6! cm) rain. when bottom of wood or metal cabinet is
protected by not less than 1/4" (0.64 cm) flame retardant millboard
covered with not less than No. 28 MSG sheet steel, 0.0!5" (0.4 ram)
stainless steel, 0.024" (0.6 ram) aluminum or 0.626" (0.5 mm) copper.
30" (76.2 cm) milK. clearance between the top of the cooking
platform and the bottom of an unprotected wood or metal cabinet.
Product dimensions
43" (109.2 cm)
overall height
27-3/4"
(70.5 crn)
j
depth
30 _
(762 cm)
width
36" (91.4 cm)
cooktop height
with feet
loosened
I-1/2 turns
When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm)
countertop -- front of oven door protrudes 1-7/8" {4.8 cm) beyond
24" (61 cm) base cabinet.
And-t@ bracket:
The floor
anti-tip
bracket
must
be
installed.To
install
the anti-tip
bracket
shipped
with
the range,
see Page 7 and the anti4ip
bracket
template.
Electrical requirements
Electrical
Shock
Hazard
EmectricaHy
ground
range.
Failure
to follow
these
instructions
can
resumt in death,
fire, or emectrical
shock.
If codes
permit
and a separate
ground
wire
is used,
it is recommended
that
a
qualified
electrician
determine
that the
ground
path
is adequate.
Do not ground
to a gas pipe.
Check with
a qualified
electrician
if you
are not sure
range
is grounded.
Do not have
a fuse
in the neutral
or
ground
circuit.
a fouFvvire
or three-wire,
single-
phase,
120/240-volt,
60-Hz,
AC-only,
electrical
supply
is available,
a
50 amp
maximum
circuit
protection
is
required
(or, if specified
on the
model/serial
rating
plate,
when
a four-
wire
or three-wire,
single-phase
120/208-
volt,
60 Hz, AC-only
electrical
supply
is
available,
a 40 amp
maximum
circuit
protection
is required),
fused
on both
sides
of the
line. A time-delay
fuse
or
circuit
breaker
is recommended.The
model/serial
rating
plate
is located
on the
oven
frame
behind
the drawer.
Wire
sizes and connections
must
conform
to the
requirements
of the
National
Electrical
Code, ANSl/NFPA
70 --
latest
edition
x_or CSA Standard
C22.1,
Canadian
Electrical
Code,
Part 1 -- latest
edition
__ and aii local
codes
and ordinances
for the kilowatt
rating
of the range.
Copies of the standards
listed may be
obtained
from:
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
_ CSA hsternational
8501 East PleasantValby
Road
Cleveland, Ohio 44131-5575