Power Supply Cord
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Direct Wire
Electrical
Shock Hazard
Disconnect
power before servicing.
Use 8 gauge copper
or 6 gauge aluminum
wire.
Electrically
ground
range.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
1=
2.
3.
Disconnect
power.
Use Phillips screwdriver to remove the terminal block cover
screw located on the back of the range. Pull cover down and
toward you to remove cover.
Remove plastic tag holding three 10-32 hex nuts from the
middle 3ost of the terminal block.
Feed the power supply cord through the opening in the
cord/conduit
plate on bottom of range. Allow enough
slack to easily attach the wiring to the terminal block.
Tighten strain relief screw against the power supply cord.
Style 2: Direct wire strain relief
Use Phillips screwdriver to remove screws from panel on
back of range.
4=
Add strain relief.
Style 1: Power supply cord strain relief
Assemble a UL listed strain relief in the opening.
i
i
A
A. UL listed strain relief
6