System Details
Technology and Features Memory Type
Chassis
Unit Environment and
Operating Conditions
Hard Drive Interfaces
Supported
Front Panel
Cooling Solutions
Supported
Slots Supported
Front I/O
Rear I/O
Drive Bays
Internal Speaker
Security
Power Supply
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and
cold, to ensure that unit is operated within the specified operating range.
Leave a 4 in (10.2 cm) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are
subject to each other's re-circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint,
dust and other foreign matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must
be provided on the enclosure, and the same operating guidelines listed above will still apply.
Temperature Range
Relative Humidity
Maximum Altitude
(unpressurized)
NOTE: Operating temperature is de-rated 1.0 deg C per 1000 ft (300 m) to 10,000 ft (3000 m) above sea
level, no direct sustained sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited
by the type and number of options installed.
DA - 12668 North America — Version 17 — May 21, 2008
HP Compaq dx2300 Microtower Business PC
PC2-5300 DDR2 SDRAM (667-MHz) non-ECC
Up to 2-GB system memory standard
Up to 4-GB system memory supported
Serial ATA
Power button
Power On LED
HDD Activity LED
Power Supply Fan (variable speed)
Active heatsink (variable speed)
Chassis fan (variable speed)
Four (4) full-height expansion slots
Two (2) USB 2.0 ports
Standard Micro ATX I/O connectors, including four (4 ) USB 2.0 ports
Two (2) 5-1/4" external
One (1) 3-1/2" external
Two (2) 3-1/2" internal
Standard
Padlock loop
Kensington Lock Support
250-watt ATX Power Supply – PFC/non-PFC with a 115v/230v line switch
Operating
Non-operating
Operating
Non-operating
Operating
Non-operating
50° to 95° F (10° to 35° C)
-22° to 140° F( -30° to 60° C)
10% to 90% (non-condensing at ambient)
5% to 95% (non-condensing at ambient)
10,000 ft (3048 m)
30,000 ft (9000 m)