Please read ALL instructions before installing. Two people are
recommended to install this product. Ifa new electrical outlet
is required, have the outlet installed by a qualified electrician
before installing
unit. See#5 in Preliminary
Instructions
following.
Preliminary
Instructions
Do the following before starting to install unit. See illustrations
below.
1. Check window opening size - the mounting parts furnished
with this air conditioner are made to install in a wooden
sill double-hung
window. The standard parts are for a
window opening of 31 "(711 mm) minimum to 42"( 1067
rc_n) maximum width. Open sash to a minimum of 19"
(483 mm). (FIG. 1)
2. Check condition
of window - all wood parts of window
must be in good shape and able to firmly hold the needed
screws. If not, make repairs before installing unit.
WINDOW
SASH SEAL
3/4"
LONG
HE)(
HEAD
SCREW
WASHERHEAD
FRAME
ASSEMBLY
(LEII)
SDE
RETAINER
SEAL-BOI
tOM
RAIL TC UNIT
I/2'LOFIG
SCREWS
AND
"_i
FRAME
O_'KN JTS
_
ASSEMBLY
\._
_#W-!
(lEFT)
OCKNJ
[
_
WINDOW
_!IPPORT
3/4 'LONG
D_____
"
BRACKET
BOLT
SI
ANGI
BRACKET
3. Check your storm
windows - if your storm window
frame does not allow the clearance required, correct by
adding a piece of wood as shown in FIG. 2, or by removing
storm window while room air conditioner is being installed.
(continued)
FIG. 1
_
SASH
T
19" MIN.
STORM
WINDOW
FRAME
OR
OTHER OBSTRUCTION
FIG. 2
[_SASH
1
19" MIN_
112"MIN
1 1/2" MIN.
ENTIRE STOOL. FASTEN
STORM WINDOW FRAME OR
WITH TWO NAILS OR
OTHER OBSTRUCTION
SCREWS.
309000906(11/03)

Advertisement

loading

Summary of Contents for Frigidaire FAS156N1A2

  • Page 1 Installation Instructions For Heavy Duty Please read ALL instructions before installing. Two people are recommended to install this product. Ifa new electrical outlet WINDOW SASH SEAL is required, have the outlet installed by a qualified electrician before installing unit. See#5 in Preliminary Instructions following.
  • Page 2: Tools Required

    4. CHECK FOR ANYTHING THAT COULD BLOCK Tools Required AIRFLOW - check area outside of window for things a large flat blade screwdriver such as shrubs, trees, or awnings. Inside, be sure tape measure furniture, drapes, or blinds will not stop proper airflow. adjustable wrench or pliers pencil 5.
  • Page 3 Window Mounting Assemble Window Remove Chassis Filler Panels 1. Place cabinet on floor, a bench, or a table. STRAP/HANDLE NOTE: Do not use strap for lifting unit. It 2. Slide 'T' section of window filler panel into side retainer is for sliding chassis WITHIN cabinet only (to aid in cleaning, on the side of the cabinet (see Figures 2-3).
  • Page 4 Place Cabinet Install Support Window Bracket 1. Open window and mark 1. Hold each support bracket flush against outside of sill, center of window stool. and tight to bottom of cabinet as shown below. Mark brackets at top level of sill, and remove. MARK 2.
  • Page 5 Extend Window Filler Install Chassis into Panels Cabinet Install Front to Unit 1. Carefully raise window to expose filler panel locking 1. Lift chassis and carefully slide it into installed cabinet. screws. Loosen screws so filler panels slide easily. 2. _ DO not push on controls OR finned coils.
  • Page 6: Installation

    Thru-The-Wall Installation NOTE: Consult local building codes prior to installation, Carefully measure and cut an opening with t he following dimensions. See FIGS. 1 and 2. or a qualified carpenter. Select Wall Location WIDTH "X" = 26-3/4" (67.9cm) plus twice the thickness of framing material used.
  • Page 7 NOTE: If wall thickness is 8-1/2" or more, add aluminum flashing over bottom of frame opening to assure no water can FIG. 2 enter area between inner and outer wall. 1" LONG WOOD SCREW OPTIONAL: Support brackets may be used. Installation brakcets are recommended for walls under 5"...
  • Page 8: Masonry Construction

    OPTIONAL: Caulking and installation of trim on interior wall may be done. You can buy wood from your local lumber or hardware supply. On the outside, caulk openings around top and sides of cabinet, and all sides ofwtx_d sleeve to the opening. NOTE: See Step 7, Item 3 of Window Mounting Instructions for bottom rail seal location.

This manual is also suitable for:

Fas185m2a1