Download Print this page

Tools Required - Frigidaire FAS156N1A2 Installation Instructions Manual

Heavy duty

Advertisement

4. CHECK
FOR ANYTHING
THAT COULD
BLOCK
AIRFLOW
- check area outside of window for things
such as shrubs, trees, or awnings. Inside, be sure
furniture, drapes, or blinds will not stop proper airflow.
5. Check the available electrical service - power supply must
be the same as that shown on the unit serial nameplate.
(See Owner's Guide for serial plate location.) Power cord
is 48"long. Be sure you have an outlet near.
Tools
Required
a large flat blade screwdriver
tape measure
adjustable wrench or pliers
pencil
Level
Socket wrenches
Phillips screwdriver
All models have a 3-prong service plug to provide proper
service and safe positive grouding. Do not change plug in
any way. Do not use an adapter plug. If your present wall
outlet does not match your plug, call a qualified electrician
to make the needed change.
Avoid
fire
hazard
or
electric shock. Do not use an extension
cord or an adapter plug. Do not remove
any prong from the power cord.
Grounding
type
wall receptacle
/_,
tl circumstances
cut,I
r" _
_ remove, orbypass the I
I (l', lP groundingprong
from I
power supply cord_
with 3-prong
grounding
plug.
6. Carefully
unpack air conditioner
- remove all packing
material. Protect floor or carpet from damage. Two
people should be used to move and install unit.
Hardware
(in plastic
bag)
Washer Head
Locking Screw
For window panels
3/4 Long Hex-
ft
Head Screw
Safety Lock
@_
1/2"LongScrew
and Locknut
%_
3/4" Long Flat
Head Bolt and
Locknut
Sill Angle Bracket
Long hex-head
locking screw for
top angle, side
retainer 5/16"
Long
4 ea.
2 ea.
10

Advertisement

loading

This manual is also suitable for:

Fas185m2a1