Please real ALL installations before installing. Two
or more people are recommended
to install this
product. If a new electrical outlet is required, have
the outlet installed by a qualified electrician before
installing unit.
Preliminary
Instructions
Do the following before starting to install unit, See
illustrations below.
1, Check
window
opening size-
the mounting
parts furnished
with
this air
conditioner
are
made to install in a wooden sill double-hung
window.
The standard
parts are for a window
opening of 32"(812 mm) minimum
to 43"(1092
mm) maximum width. Open sash to a minimum
of 20" (508 mm), (FIG, 1 )
2, Check
condition
of window-
all wood parts
of window
must be in good shape and able to
firmly
hold the needed screws,
If not, make
repairs before installing unit,
3, Check
your
storm
windows-
if your storm
window frame does not allow the
clearance
required, correct by adding a piece of wood as
shown in FIG. 2, or by removing storm window
while room air conditioner is being installed,
(Continued)
1/2" MIN.
SASH
J
t
20" MIN.
STORM WINDOW FRAME OR
OTHER OBSTRUCTION
Fig. 1
FOAM
SASH SEAL
DOUBLE
SIDED SEAL
SIDE
ACCORDION
(RIGHT)
1/4,,x11/2
,,
BOLT
MOUNTING
BRACKET
END CAP &
ANGLE
LEVELING
LEGS
BRACKET
SIDE
ACCORDION
(LEFT)
SASH
f
'
t
I
il 1/2" MIN.
20" MIN.
1/2" MIN.
--_i
I_--
I
T
% Zct ss
STORM WINDOW FRAME OR
ENTIRE STOOL. FASTEN
OTHER OBSTRUCTION
WITH TWO NAILS OR
SCREWS.
Fig. 2
P/N:819042102-01

Advertisement

loading

Summary of Contents for Frigidaire FAS157P1A1

  • Page 1 installation Instructions for Heavy duty Please real ALL installations before installing. Two or more people are recommended to install this product. If a new electrical outlet is required, have the outlet installed by a qualified electrician before installing unit. Preliminary Instructions FOAM Do the following before starting to install unit, See...
  • Page 2 4. CHECKFOR ANYTHING THATCOULD BLOCK Tools Required AIRFLOW-check area outside of window things such as shrubs, trees, or awnings. ,/ Flat blade screwdriver Inside, besure furniture, drapes, orblinds will ,/ Tape measure not stop proper airflow. ,/ Adjustable wrench or pliers ,/ Pencil ./ Spirit level 5.
  • Page 3: Installation

    Window installation E. Be certain the proper electrical outlet is within reach of the installation. All wiring should be in Because the compressor located accordance with local national electrical controls side of the unit (right side), this side codes. will be heavier and more awkward to manipulate. Inadequate support on control side of the unit F.
  • Page 4: Window Installation

    Window installation 2. Preparation to Remove the Air Conditioner From Slide-Out Chassis Place unit on floor, remove total of (4) Philips screws securing the chassis to the cabinet. There are (2) screws on each side. The set of screws closest to the front of the unit secure the front panel...
  • Page 5 Window installation 5. Installation of Mounting Brackets and the (TOP VIEW) Sealing Strip Wslot_ ° NOTE: Windows come in a variety of different o ..o..styles. Therefore, it may be necessary to modify Bracket Assembly or improve your particular installation. Leve soppor Brackets...
  • Page 6 Window installation 6. Installation of the cabinet A. Align one hole in the bottom of the cabinet with one hole in the bracket assembly. Secure the cabinet to the bracket using (3) 1/4" screws provided. Repeat the same procedure on the opposite side of the cabinet.
  • Page 7 Window installation 9. Complete the installation A. Cut the foam to fit the opening between the Foam top of the inside and outside window. See (Fig. 13). B. Some installations require additional sealing around the window and air conditioner. Fig. 13 Check leaks seal...
  • Page 8 Waft Installation Carefully measureand cutan opening with the NOTE: Consult local building codes prior to following dimensions. FIGS. 1 and 2. installation, ora qualified carpenter. WIDTH "X"=265/8" (68cm) plus twice thickness of framing material used. Select Wall Location HEIGHT"Y"= 185/8'' (47cm) plus twice thickness...
  • Page 9 NOTE: If wallthickness is8-1/2" ormore, 4. OPTIONAL: Support brackets may be used. aluminum flashing over bottom frame Installation brackets are recommended opening to assure no water can enter area walls under 5" thick. Refer to Step4 between innerand outerwall. Window Mounting for assembly of support brackets.
  • Page 10: Masonry Construction

    RECOMENDED: Caulking and installation trim on interior wall be done. You can buy wood from your local lumber or hardware supply. outside, caulk openings around sides of cabinet, sides ofwood sleeve to theopening. Masonry Construction 1. Cutor builda wall opening in the masonry wall similar...