8. Storage
IMPORTANT: Always unplug the vacuum cleaner
from the electrical outlet and rewind the power cord
as directed before storing.
NOTE: Always store the vacuum cleaner base
down.

9. Troubleshooting

WARNING: To reduce the risk of personal injury,
unplug the vacuum cleaner before performing
maintenance/troubleshooting checks.
PROBLEM: Vacuum cleaner won't run
Cause:
Not properly plugged into electrical
outlet.
Solution: Plug in securely.
Cause:
No electricity in the electrical outlet.
Solution: Check fuse or breaker.
Cause:
On/off switch not turned on.
Solution: Push on/off switch to 'on'.
Cause:
Motor thermostat has tripped.
Solution: Switch off and unplug the vacuum
cleaner. Leave for one (1) hour before
switching the vacuum cleaner back on.
Cause:
Blown fuse/tripped breaker.
Solution: Reset circuit breaker or replace fuse.
PROBLEM: Cleaner won't pick up/loss of
suction.
Cause:
Dirt container not installed properly.
Solution: Review dirt container replacement.
Cause:
Dirt container full or blocked.
Solution: Empty dirt container.
Cause:
Clogged filters.
Solution: Remove, clean and replace filters.
PROBLEM: Dust escaping from the vacuum
cleaner.
Cause:
Dirt container full.
Solution: Empty dirt container.
Cause:
Dirt container not installed.
Solution: Review dirt container replacement.
Cause:
Filter not installed completely.
Solution: Remove, clean and replace filter.
PROBLEM: Accessories won't pick up.
Cause:
Accessories are not attached correctly.
Solution: Refer to section 5.
8
15:54
Page 9
10. UK Service & Help
Vax Care 0870 6061248
Monday-Friday. 9.00am to 5.00pm.
An answerphone will be available out of these
hours. Any queries or concerns about using your
Vax, call the Vax Careline. Calls are charged at the
UK national rate.
Please make a note of the model number and serial
number of your Vax before calling. There are over
400 approved Vax Service Agents in the UK. For
the nearest Vax Service Agent, please call the Vax
Careline or visit www.vax.co.uk

11. Technical Specification

Voltage:
Wattage:
Capacity:
Filters:
Cord length:
Weight:
Subject to technical change without notice.
220-240V ~50Hz
1800W-2000W (dependant on
model)
2.7 litres approx
Washable central HEPA filter [with
filter shroud]
Pre-motor filter
Post-motor filter
5.6m (approx)
9.0kg

Advertisement