Installation
gasses. Consequently it is possible to extend the
flue system to a greater distance than that pro-
vided by the standard horizontal co--- axial flue.
If either an additional 45° or 90° accessory elbow
is used then the maximum permissible length of
either pipe must be reduced by 0.90 m or 1,65 m
respectively.
Fig. 6.6
Two restrictors with different size are supplied
with the twin pipe kit and have to be installed
between the boiler and the air intake adapter
(Fig. 6.7).
Air intake adapter
Restrictor
Gasket
Fig. 6.7
For the correct use of the restrictors with twin
pipes refer to Tab. 6.2.
Equivalent length
(air duct + flue duct)
Between 1 and 15 m
More than 15 m up to 30 m
Tab. 6.2
Vertical--- roof kit (Fig. 6.8)
This kit allows vertical termination of the flue pipe
through the roof. The kit is 1.2 m in length. Exten-
sion pieces (Co--- axial) are also available which al-
lows the flue system to be extended to a total
overall maximum permissible length.
Optional 45° and 90° elbows can be used to offset
the flue route.
Each additional elbow reduces the overall accept-
able length of the flue system as follows:
45° reduce length by 0.5 m.
90° reduce length by 1 m.
90° =--- 1,65 m
45° =--- 0,90 m
Fig. 6.8
6.9
Connection to the electricity supply
1 Remove the front panel of the case (see the
section 9.2 in this manual).
2 Remove the screws I and J (Fig. 6.9).
3 Loosen the screws K.
Restrictor
ø 50 mm
ø 55 mm
max = 8.5 m

Electrical connections

90° =--- 1m
45° =--- 0,5m
27