Built In Time Switch - Biasi RIVA COMPACT HE M96.24SM/C User Manual And Installation Instructions

Wall hung, fan flue, room sealed, high efficiency gas boiler
Hide thumbs Also See for RIVA COMPACT HE M96.24SM/C:
Table of Contents

Advertisement

Instructions for use
The appliance operation light 10 will flash every 4
seconds.
10
Fig. 2.11
10
Fig. 2.12
When you do not expect to use the boiler for a long
period:
1 Switch off the electricity supply to the boiler, by
means of the fused spur isolation switch;
2 Shut off the gas supply cock 14 and the valves
for the water circuits fitted under the boiler
(Fig. 2.13).
3 Empty the water circuits, if necessary, as
shown in the installation instructions in the sec-
tion maintenance.
14
Closed position
Fig. 2.13
2.7
Built in time switch (combi)
The combi boilers are equipped with a built in elec-
tronic time switch (5, Fig. 1.3 on page 2) which
8
controls the c.h. operation.
G
8
F
Fig. 2.14
Display and control panel
A Mode selector switch
B Reset button
C Enter button
D Increase "+" setting button
E Decrease " --- " setting button
F On--- off button
G Time display
H ON--- OFF display
Setting the current time
Note: with a new unit or when the reset button B
has been pressed and the selector switch A is to
the
position, the time display G is flashing.
Set the mode selector switch A to the
and press the buttons D or E until the current time
appears in the display G.
The clock starts by moving the switch A to the
AUTO position.
Setting example shown in Fig. 2.15:
Current time 16.30.
E
D
C
H
A
B
position
7