Electrolux E36EC70FSS2 Installation Instructions Manual page 4

Electric cooktop
Hide thumbs Also See for E36EC70FSS2:
Table of Contents

Advertisement

Available languages

Available languages

EJectricaJ Connection
Connect the flexible armored cable that extends from the
surface unit to the junction box using a suitable strain
relief at the point the armored cable enters the junction
box. Then make the electrical connection
as follows.
Electrical
ground
is required
on this
appJiance.
This appJiance
is equipped
with
a
copper
conductor
fJexibie
cabJe.
Jf connection
is
made
to aJuminum
house
wiring,
use only
speciaJ
connectors
which
are approved
for joining
cooper
and aJuminum
wires
in accordance
with
the National
EiectricaJ
Code and
JocaJ codes
and ordinances.
improper
connection
of aJuminum
house
wiring
to
copper
Jeads can result
in a short
circuit
or fire.
Follow
the connector
manufacturer
recommended
procedure
closely.
This appliance is manufactured with a frame connected
green (or bare copper) ground wire.
DO NOT ground
to a gas supply
pipe.
DO NOT connect
to eJectricaJ
power
suppJy
untiJ
appJiance
is permanentJy
grounded.
Connect
the
ground
wire
before
turning
on the power.
Where local codes permit
connecting
the appliance-
grounding
conductor
to the neutraJ (white)
wire:
if your cooktop
is to be connected
to a 3-wire
grounded
junction box (see figure
4):
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box:
connect appliance and power supply cable wires as
shown in figure 4.
Cable from Power Supply
White Wire
(Neutral)
Red
Wires ]
Wires
Box
(Neutral)
Ground Wire
U.L-Listed Conduit
Bare or Green Wire)
Connector (or CSA listed)
Cable from appliance
Figure 4
3-WIRE GROUNDED JUNCTION BOX
You may
not ground
the cooktop
through
the neutral
(white)
wire
if cooktop
is used
in a new
branch
circuit
instaiJatJon
(1996
NEC),
mobiJe
home,
recreational
vehicJe,
or where
local
codes
do not
permit
grounding
through
the
neutraJ
(white)
wire.
When
grounding
through
the
neutraJ
(white)
wire
is prohibited,
you must
use a
4-wire
power
suppJy
cabJe. See Figure
5. Failure
to heed this
warning
may result
in electrocution
or
other
serious
personal
injury.
if cooktop
is used
in a new
branch
circuit
installation
(1996
NEC), mobiJe
home,
recreational
vehicle,
or where
JocaJ codes
DO NOT permit
grounding
through
the neutral
(white)
wire:
1. Disconnect the power supply.
2. Separate the green (or bare copper) and white
appliance cable wires.
3. In the circuit breaker, fuse box or junction box:
connect appliance and power supply cable wires as
shown in figure 5.
Cable from Power Supply
Ground Wire
Red
--
Black
(Bare or Green
Wire)
Conduit
Junction Box
Connector (or CSA listed)
Cable from appliance
Figure 5
4-WIRE GROUNDED JUNCTION BOX
Jf connecting
to a 4-wire
power
suppJy cabJe eJectricaJ system, the appliance
frame
connected
ground wire MUST NOT be connected
to
the neutral
wire of the 4-wire electrical
system.