Please Read Carefully - Frigidaire FGFB66ASD Installation Instructions Manual

30" gas range with sealed top burners
Table of Contents

Advertisement

Available languages

Available languages

Manual
Flare
Flexible
FlareUnion
Pressure
Shutoff
Union
Appliance
Adaptor
Regulator
5. Read electrical connection details below
and connect electricity to range.
off
\
ServiceShut-OffValve ElectricIgnition modelsonly_
(Shownin ON Position).
Besure lever isin the "On" positionwhen
installationiscomplete
a) install an external manual gas shut-off valve to gas supply
line in an easily-accessible
location outside of the range.
Be sure you know how and where to shut-off the gas
supply to the range.
b)
Instait 1/2" flare union adapter to pressure regulator.
c)
Attach appliance conduit to flare union on regulator.
d)
install flare union adapter to external manual shut-off
valve.
e)
Attach appliance conduit to flare union on shut-off valve.
f)
Make sure service shut-offvalve on pressure regulator is
in "ON" position.
g)
Check for leaks. Turn the gas supply on to the range and
use a liquid leak detector at all joints and conduits to
check for leaks in the system.
Do not use a flame to check for gas leaks.
Checking
Manifold Gas Pressure
Disconnect the range and its individual shut-off valve from
the gas supply piping system during any pressure testing of
that system at test pressures
greater than 14" of water
column pressure (approximately
1/2" psig).
The appliance must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 14" of water column pressu re
(approximately
1/2" psig).
If it should be necessary to check the manifold gas pressure,
connect manometer (water gauge) or other pressure device
to the top burner right rear orifice. Using a rubber hose with
inside diameter of approximately 1/4," hold tubing down tight
over orifice. Turn burner valve on.
For an accurate pressure check have at least two (2) other
top burners burning. Be sure the gas supply (inlet) pressure
is at least one inch above specified range manifold pressure.
The gas supply pressure should never be over 14" water
column. When properly adjusted for Natural Gas the manifold
pressure is 4." (For LP/Propane Gas the manifold pressure
is 10.")
Before servicing,
disconnect
electrical
supply at circuit breaker, fuse or power cord.
Electric Requirements: An individual, properly grounded and
polarized branch circuit protected by a 15 amp. circuit breaker
or time delay fuse. See serial plate for proper voltage.
Extension Cord Precautions:
Because of potential safety hazards under certain conditions,
we strongly recommend
against the use of any extension
cord. However, if you still elect to use an extension cord, it is
absolutely necessary that it be a UL listed 3-wire grounding
type appliance extension cord and that the current carrying
rating of the cord in amperes be equivalent to or greater than
the branch circuit rating. Such extension cords are obtainable
through your local service organization.
PLEASE READ CAREFULLY!
For personal
safety, this product must be properly grounded.
Grounding Instructions
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong grounding wall receptacle to minimize the possibility
of electric shock hazard from this appliance. The customer
should have the walt receptacle and circuit checked by a
qualified electrician to make sure the receptacle is properly
grounded and polarized.
Preferred Method
/,
fll
II
TypeGrounding
Wall
Receptacle
Do Not, Under
Any Circumstances, I
Cut, Remove,
|
or Bypassthe
J
_
Power Supply
Cord with
_'
3-Prong
Grounding
_lb
Plug
Where a standard two-prong wall receptacle is encountered,
it isthe personal responsibility and obligation of the customer
to have it replaced with a properly grounded three-prong wall
receptacle.