Electrical
Shock Hazard
• Electrical ground is required on this appliance.
• Do not connect
to the electrical
supply until
appliance is permanently
grounded.
• Disconnect
power to the junction
box before
making the electrical connection.
• This
appliance
must
be
connected
to
a
grounded,
metallic, permanent
wiring system,
or a grounding
connector should be connected
to the grounding
terminal
or wire lead on the
appliance.
Failure to do any of the above could result in a
fire, personal injury or electrical shock.
Grounding
Instructions
For appliances
connected
to a junction
box, use U.L-
listed conduit connectors. Complete electrical connection
according to local codes and ordinances.
.
Where
local
codes
permit
connecting
the
cabinet-grounding
conductor
to the neutral
(white) junction box wire (see Figure 6)
(The 3-conductor
cord or cable must be replaced
with a 4-conductor
cord or cable where grounding
through the neutral conductor
is prohibited
in mew
installations,
mobile homes, recreational vehicles or
in other
areas where
local codes do not permit
neutral grounding.)
A.
Disconnect the power supply.
B. Connect together the 3 wires: green (bare) and
white
appliance
cable wires and the neutral
(white) wire in the junction box.
C. Connect
the 2 black wires together,
then the
two red wires together.
Ground
(White Wire)
Cable from
Power Supply
_Junction
Box
Bareor
Green Wire
Conduit
Cable from
Connector
Range
(or CSAlisted)
Figure
6 - GROUNDED
NEUTRAL
.
Where
local
codes
DO
NOT
permit,
or if
connecting
to a 4-wire
electrical
system,
DO
NOT connect the cabinet-grounding
conductor
to the neutral
(white)
junction
box wire (see
Figure 7)
A
Disconnect the power supply.
B. Separate the bare copper and white appliance
cable wires.
C. Connect the white appliance cable wire to the
neutral (white) wire in the junction box.
D. Connect
the 2 black wires together,
then the
two red wires together.
E. Connect the bare copper grounding wire to the
grounding wire in the junction
box.
Junction
Cable from
Power Supply
Bare --_
Wire
Wire
Wire
.
Conduit
Cable from
Connector
Range
(or CSA listed)
Figure 7 - 4-WIRE ELECTRICAL SYSTEM
Locate junction box as shown in Figure 8.
If a service cord is used, the wall receptacle should
be located
in accordance
with
the
dimensions
below.
Center
Line of
Range
7, Max:
(17,8 Cm Max:) I
Center
Line of
Locate Electrical Hook-up
Range
Inside Shaded Area
Figure 8
5