Download Print this page

Frigidaire FEF455WFBC Installation Instructions Manual page 4

40" electric range
Hide thumbs Also See for FEF455WFBC:

Advertisement

Available languages

Available languages

TO GAIN ACCESS TO LOWER TERMINAL
BLOCK
BEND LOWER BACK COVER PLATE ALONG ROW
OF HOLES SHOWN HERE.
Figure 3
B.
Remove the 3 loose nuts (after you removed the
rubber band) on the terminal
block using 3/8"
nut driver or socket.
C. Connect the neutral of the copper power supply
cord to the center silver-colored terminal of the
terminal
block, and connect the other wires to
the outer terminals. Math wires and terminals by
color (red wires connected to the right terminal,
black wires connected to the left terminal).
D. Lower the terminal
cover and replace the 3
screws.
Silver Colored Terminal
A CONSUMER
SUPPLIED STRAIN-RELIEF
MUST BE INSTALLED
AT THIS LOCATION
Grounding
TO FUSED DISCONNECT
BOX OR
APPROVED WIRING
DEVICE FOR
3-WIRE COPPER POWER SUPPLY CORD (40 AMPERES)
Figure 4
Do not loosen nuts, wich secure the
factory-installed
range wiring to terminal block while
connecting range. Electrical failure or loss of electrical
connection may occur.
,
Four Conductor
Wire
Connection
to Range
(mobile homes)
A.
Remove the 3 screws at the lower end of the
rear wire cover, then raise the lower end of the
rear wire cover (access cover) upward to expose
range terminal connection block.
B.
Remove the ground
strap from the terminal
block and from the appliance frame. Retain the
ground screw.
C. Connect the ground wire (green) of the copper
power supply cord to the frame of the appliance
with the ground
screw, using the hole in the
frame where the ground strap was removed (see
Figure 5).
D. Connect the neutral (white) wire of the copper
power supply cord to the center silver-colored
terminal of the terminal block, and connect the
other wires to the outer terminals.
E.
Lower the terminal
cover and replace the 3
screws.
Silver Colored Terminal
A CONSUMER
SUPPLIED STRAIN-RELIEF
MUST BE INSTALLED
AT THIS LOCATION
Ground
TO FUSED DISCONNECT
BOX OR
APPROVED
WIRING
DEVICE FOR
4-WIRE COPPER POWER SUPPLY CORD (40 AMPERES)
NOTE:
BE SURE TO REMOVE THE SUPPLIED GROUNDING
STRAP
Figure 5
Electrical
Connection
to the
Residence
Electrical
System
The appliance
may be connected
directly to the fused
disconnect
or circuit
breaker
box through
flexible,
armored
or nonmetallic
sheathed
copper
cable (with
grounding wire). Locate the junction box to allow 2 to 3
feet of slack in the line so that the range can be moved
if servicing is ever necessary. Do not cut the conduit.
A U.L.-listed
conduit
connector
must be provided
at
each end of the power supply cable (at the appliance
and at the junction box). Wire sizes (copper wire only)
and connections
must conform
with the rating of the
appliance.
4