PRE-INSTALLATION
REQUIREMENTS
Tools Required for Installation:
1.
1/4 in. nut driver
2.
3/8 in. socket with ratchet.
3.
3/8 in. open end wrench.
4.
7/16 in. socketwith
ratchet.
5.
9/16 in. open end wrench.
6.
Channel-lock adjustable pliers.
7.
Carpenter's level.
ELECTRICAL
REQUIREMENTS
CIRCUIT - Individual, properly polarized and grounded
15 amp. branch circuit fused with 15 amp. time delay
fuse or circuit breaker.
POWER SUPPLY - 2 wire, with ground, 120 volt, single
phase, 60 Hz, Alternating Current. NOTE: The use of this
washer wi_ power created by gas bowered generators,solar
powered generators, wind powered generators or any other
generator other than the local utility company is not
recommended.
into an appropriate, copper wired receptacle that is
properly installed and grounded in accordance with all
local codes and ordinances or in the absence of local
codes, with the National Electrical Codes, ANSI/N FPA
70 (latest edition). If in doubt, call a licensed electrician.
DO NOT cut off or alter the grounding prong on the
power supply cord. In situations where a two-slot
receptacle is present, it is the owner's responsibility to
have a licensed electrician replace it with a properly
grounded three prong grounding type receptacle.
WATER
SUPPLY
REQUIREMENTS
Hot and cold water faucets MUST be installed within
42 inches (107 cm) of your washer's water inlet. The
faucets MUST be 3/4 inch (1.9 cm) garden hose type
so inlet hoses can be connected. Water pressure MUST
be between 30 and 120 pounds per square inch (maximum
unbalance pressure, hot vs. cold, 10 psi.)Your water
department can advise you of your water pressure. The hot
water temperatureshouldbe about 140degrees F(60 degrees
c).
DRAIN
REQUIREMENTS
1.
Drain capable of eliminating 17 gals (64.3 L) per
minute.
2.
A standpipe
diameter
of 1-1/4 in. (3.18
cm)
minimum.
3.
The standpipe height above the floor should be:
Minimum height:
24in. (61 cm)
Maximum height:
96 in. (244 cm)
OUTLET RECEPTACLE - Properly grounded 3-prong
receptacle to be located so the power supply cord is
accessible when the washer is in an installed position.
NOTE: GFI (Ground Fault Interrupter) receptacle is not
required.
GROUNDING
REQUIREMENTS
_
Improper connection of the equipment
grounding conductor can result in a risk of electrical
shock. Check with a licensed electrician if you are in
doubt as to whether the appliance is properly grounded.
.
The washer MUST be grounded. In the event of
malfunction or breakdown, grounding will reduce
the risk of electrical
shock by a path of least
resistance for electrical current.
2.
Since yourwasher is equipped with a power supply
cord having an equipment-grounding
conductor
and a grounding plug, the plug MUST be plugged
NOTE:
O
BACK
96 in.
(244 cm)
Max.
24 in.
(61 cm)
Min.
Drain hose attached to the washer can reach a 58
in. (147 cm) high standpipe. For higher standpipe
use hose P/N 134049201, availablefrom an authorized
parts distributor. If drain is less than 24 in. (61 cm),
install a siphon break kit, available at your local
hardware store.

Advertisement