INSTALLATION--GAS CONNECTIONS
r_
PROVIDE ADEQUATE
GAS SUPPLY
This cooktop
is designed to operate on natural gas
at 4" of water column manifold
pressure and 7" of
water column (W.C.) supply pressure. It is shipped
from the factory set for natural gas. The convertible
pressure regulator
supplied with the unit must
be connected
in series with the manifold
of the
cooktop and must remain in series with the supply
line regardless of whether
natural or LP. gas is
being used.
FOR PROPER OPERATION, THE MAXIMUH INLET
PRESSURETO THE REGULATOR MUST BE NO HaRE
THAN 14" OF WATER COLUMN PRESSURE.For
checking the regulator, the inlet pressure must
be at least 1" W.C.. (or 3.4 KPA) greater than the
regulator
output setting. If the regulator
is set for 4"
W.C. of water column pressure, the inlet pressure
must be at least 5" W.C. If the regulator
is set for
10" W.C., the inlet pressure must be at least 11"
W.C.. The gas supply line to the cooktop should be
1/2" or 3/4" pipe.
J_
INSTALL REGULATOR
NEVER REUSE OLD CONNECTORS WHEN
INSTALLING THIS COOKTOP.
WARNING: Never reuse o ld
flexible connectors.
The use of old flexible
connectors
can cause gas leaks and personal
injury. Always use new flexible connectors
when
installing a gas appliance.
Screw a section of pipe onto
the inlet end of the pressure
regulator
and install the
coupling.
Pressure -_l
Regulator
Coupling
_
To reduce the likelihood of gas leaks, apply teflon
tape or a thread compound
approved
for use with
LP or Natural gases to all threaded
connections.
r_
INSTALL REGULATOR ONTO
BURNER BOX BOTTOM
Screw the regulator
onto
the burner box
bottom
pipe
connection.
Hake sure the
top of the regulator
is
facing towards
the
cabinet front, easily
accessible through
the cabinet doors.
I
I
Pressure ___
Regulator
Coupling _l
Shut-Off
_
Valve _'_
l]J
Li
1
Electrical
I
Outlet 12"
I
Below
Countertop
_]
COMPLETE CONNECTION
WITH A
COUPLING
Complete the
connection
between
the regulator
pipe
coupling
and
the shut-off valve.
I
I
L--
Pressure _
Regulator
Coupling
Shut-Off
Q,
Valve _
U
i\
II Electrical
I Outlet 12"
I
Below
Countertop