For all models except KECC051 series:
For cooktops with a 3-wire cable
If your home has:
And you will be
Go to Section:
connecting to:
4-wire direct
A fused
4-Wire Cable from
disconnect
or
Power Supply to
circuit breaker
3-Wire Cable from
box
Cooktop
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,
fire, or electrical shock.
For model KECC051
series only:
Electrical Shock Hazard
Disconnect power before servicing.
Use 12 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,
fire, or electrical shock.
This cooktop is manufactured with a frame connected, green or
bare ground wire. Connect the cooktop cable to the junction box
through the UL listed or CSA approved conduit connector.
Electrical
Connection
Options
For cooktops with a 4-wire cable:
If your home has:
And you will be
Go to Section:
connecting to:
4-wire direct
A fused
4-Wire Cable from
disconnect or
Power Supply to
circuit breaker
4-Wire Cable from
box
Cooktop
A fused
3-Wire Cable from
disconnect or
Power Supply to
circuit breaker
4-Wire Cable from
box
Cooktop
3-wire direct
3-wire direct
A fused
3-Wire Cable from
disconnect
or
Power Supply to
circuit breaker
3-Wire Cable from
box
Cooktop
4-Wire Cable from Power Supply to 4-Wire Cable from
Cooktop
IMPORTANT: Use the 4-wire cable from power supply where local
codes do not permit connecting the frame-ground
conductor to
the neutral (white) junction box wire.
A. Red wires
B. Bare or green wires
C. 4-Wire cable from cooktop
D. Junction box
E. White wires
F. UL listed wire nut
G. Black wires
t4. UL listed or CSA approved
conduit connector
1. Disconnect power.
2. Remove junction box cover if present.
3. Connect the flexible cable conduit from the cooktop to the
junction box using a UL listed or CSA approved conduit
connector.
4. Tighten screws on conduit connector, if present.
5. Connect the two black wires together using the UL listed wire
nuts.
6. Connect the two red wires together using the UL listed wire
nuts.
7. Connect the two white wires together using the UL listed wire
nuts.
8. Connect the green or bare ground wire from the cooktop
cable to the green or bare ground wire (in the junction box)
using the UL listed wire nuts.
g. Install junction box cover.
10. Reconnect power.