Bosch SHX36L05UC-18 Installation Instructions Manual page 27

Table of Contents

Advertisement

Figure 26/llus. 26
Figure 27/llus. 27
ELECTRICAL
CONNECTION
_k,
WARNING:
ELECTRICAL
SHOCK
HAZARD
- Working
on an energized
circuit could result in serious
injury
or death. Only qualified
electricians
should
perform
electrical
work.
Do
not attempt
any work on the dish-
washer
electric
supply
circuit until
you are certain
the circuit is de-
energized.
_,
WARNING:
FIRE HAZARD-
Improper
electrical
work can cause
fire. Only qualified
electricians
should
perform
electrical
work.
Grounding
Instructions
The dishwasher
must
be properly
grounded
before
operating.
This
appliance
must
be connected
to a
grounded
metal
permanent
wiring
system,
or an equipment
grounding
conductor
must be run with the circuit
conductors
and connected
to the
equipment
grounding
terminal
or lead
on the dishwasher.
Make sure that the
dishwasher
is connected
to a suitable
ground
in compliance
with all local
codes or, in the absence
of a local
code, with the NATIONAL
ELECTRI-
CAL CODE in the United States or the
CANADIAN
ELECTRIC
CODE
C22.1-
latest edition
in Canada
as well as
any provincial/state
or municipal
or
local codes
that apply.
1) Retrieve
the strain
relief plate, and
install a strain
relief (not supplied)
into
the opening
on the strain
relief plate.
NOTE:
Orient
the strain relief as
shown
in Figure
26.
2) Pass the electrical
supply
cable
through
the strain
relief, as shown
in
Figure 27. Leave 3 - 4 inches
of
insulated
wire extending
through
the
strain
relief plate.
3) Tighten
the strain relief screws.
4) Slide the strain relief plate into the
junction
box, and secure
it to the
junction
box with the supplied
screw.
(Continued
on next page)
26
Electrical
Connection
I Connexion
Electrique
I Conexibn
El_ctrica

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents