Connecting To 208 Volt Circuit - Bosch HBN456AUC Installation Instructions Manual

Electric built-in single & double oven
Hide thumbs Also See for HBN456AUC:
Table of Contents

Advertisement

Available languages

Available languages

CONNECTING
TO 208 V CIRCUIT
The
ovens
are pre-wired
for connection
to 240
volt, 60 Hertz supply.
If connecting
to a 208 volt,
60 Hz. supply
a jumper
must be used across
two
terminals.
For the double
oven models
there are
two jumpers,
one for the upper
oven and one for
the lower
oven. For the single
ovens there is one
jumper.
Please
refer
to figures
below
for placement
of
jumper
for 208 volt, 60 hertz connection.
To connect
to 208 volt circuit:
1
Remove
the access
panel(s)
located
on the
back of the oven(s).
2.
Loosen
the first and second
screws in the ter-
minal
block
as shown
in applicable
figure
above.
3.
Place
the metal
jumper
between
the first
and second
screws
and tighten
screws
to
hold jumper
in place.
4.
Replace
access
panel(s).
Placing
of jumper
for single
oven
or upper oven of double
oven,
for connection
to 208 volt, 60 Hz.
Before
Jumper
Jumper
After
Placing
of jumper
for lower oven
of double
oven, for connection
to
208 volt, 60 Hz.
Before
Jumper
Jumper
After

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents