Download Print this page

Advertisement

Available languages

Available languages

Quick Links

Size : 420 X 297 (ram)
REMOVE PACKING MATERIAL
Cut the straps oil he carton and lift the carton off the drye*
Remove the dryer from the carton base
Check the dryer drum for all of the componen%
shown here
Literature
Pack
CHECK AND CONNECT VENTING
1 Check the length of the exhaust vent it MUST NOT
be longer than the
lengths shown in the chart below
If it is too long, have it repaired
or vented
elsewhere
2 Connect the dryer exhaust to the home exhaust system with rigid or semi
rigid metal duct DO NOT USE vinyl or foil duct for connecting
the dryel
Make
the transition
as short as possible
for best results
3 Check the exhaust hood on the outside wall Make
sure it is not damaged
and that it is clear
of lint buildup
Make
sure the damper
is working
properly
4 Check the exhaust for lint buildup or damage
Make
sure the duct is clean
and in good condition
Reeemm_ded
0
80 it 124 4 m)
41 fl (12 4 m)
_
_#
1
68 fl (207 m)
37 Jt ill 2"n)
2
5711
(]Z4 m)
33fl
ri0]m)
4"
(10.16 era)
3
47it
(14 3 m)
29 fl (90 m)
Use only for short-run
installation
0
74 it (226 m)
33 it (101 m)
1
6211 f189m)
29fl
(88m)
2
51ft
1155 m)
251t
176m)
25"
(6.35
¢m)
3
41 fl (12 5 m)
21 fl (6 5 m)
CONNECT POWER CORD
For gas dryers
only.
#or electric
dryers proceed
to step #3b
on the right
Plug the dryer into a 120 VAC, 60Hz
grounded
3 prong outlet
For electric
dryers
only.
For gas dryers proceed
to step #30
on the IdL
FOUR-WIRE
POWER
CORD
CONNECTION
(REQUIRED inall new constructionafter Jan 1,19%)
4-Wire
system
connections
A. External ground connector
A
_
D
B. Greet, or bare copper wire of power cord
C. _f_" (]9 cm} UL listed strain relief
D. Center silver colored terminal block screw
B
E
E. Neutral Grounding
wire (green yellow}
C J
_
_ F
E Neutral wire (white or center wire}
U
i Remove the External ground connector
screw
2 Connect the ground wire (green or unwrapped}
of the power cord to the
external ground connector
scre_
If you want to connect B(Green or bare
copper
wire of power cord} to the Neutral Post without assembling with
A(cabinet
ground}, call the service technician
3 Looser, or remove the center terminal block screw
4 Connect the neutral wire (white or center wire} of the power cord and the
appliance ground wire (greet, with yellow stripes} under the cenhal screw
of the terminal block
5 Connect the other wires to the outer terminal block screws Tighter, screws
B Tighten the strain relief screws
X [nsed the tab of the terminal block cover into your Dryer's rear panel slot
Secure the cover with a hold dowr, screw
THREE-WIRE
POWER
CORD
CONNECTION
(NOT permitted in new constructionafter Jan 1,19%)
3-Wire
system
connections
A. External ground connector
B. Neutral grounding
wire (green/yellow)
C. Cer, ter silver colored terminal block screw
D. Neuhal
wire (white or center wire}
E. s/4_' (19 cm} UL listed strain relid
] Looser, or remove the center terminal block
screw
2 Connect the neutral wire (white or center wire} of the power cord to the
centel, silver colored
terminal screw of the terminal block Tighter, screw
3 Connect fl:e other wires to outer terminal block screws
fighter, screws
4 Tighter, the strain relief screws
5 Insert fi:e tab of the terminal block cover into your DryeFs rear par,el slot
Secure the cover with a hold dowr, screw
CONNECT GAS SUPPLY
For gos mode_ only
1 Connect
the dryer to your laundry room s gas supply using a new flexible
stainless steel connector
with a 3/8" NPT fitting
Never
reuse an old flex connecto_
2 Securely
tighten all connections
be+ween the dryer and he laundry room's
gas supply Turn on the gas supply and check all connections
for leaks with
a non corrosive
leak detection
fluid
3/8" NPT Gas
/8" NPT Pipe Plug
Connection
AGA!CSA-42ertifled
Stainless
Steel
Shutoff:
Valve
Flexible
Connector
LEVELINGTHE DRYER
1 To set the dryer to the
same height as the washel,
fully retract
the leveling
feet by t_urning them coun
terclockwise,
then loosen
the legs by turning them
clockwise
.evel
Leveling Feet
2 Adiust the leveling feet only as
much as necessary
to level the
dryec
Extending
the leveling fee+
more than necessary
can cause
the dryer to vibra'e
HEATERCHECK
Perform the following
steps to check heater operation
after
removing
the literature
pack and any other obiects
from the
drum
1 Close the door and press the POWER button to turn oil the controls
2 Rotate the CYCLE SELECTOR KNOB
to select a hea'ed cycle, such as
NORMAL.
3 Press the START/PAUSE
button to start the cycle
After approximately
one minute, open the door and check for hea" if no
heat is felt after approximately
2 minutes, consuft the troubleshooting
sec
tion of the owner's
manual
FINAL CHECKS
Use the following
checklist to ma ke sure you have complet
ed all of the installation
steps
INSTALLATION
STEP
1 - REMOVE PACKING
MATERIAL
2 - CHECK AND CONNECT
VENTING
3 - CONNECT
POWER CORD
4 - CONNECT
GAS SUPPLY (For gas models only)
5-
LEVEL THE DRYER
6 - HEATER CHECK
Screws
For more information,
refer to Installation
Instructions included
in the pedestal
For accessory
installation instructions, consult the ins:allafion
instructions
included
with each accessory
LP CONVERSION
KiT
SiDE VENT
KIT - DV ]A XAA
STACKING
KIT-
SK 5AXAA
Test for proper
operation
by running
the dryer through
a
complete
cycle.
Please consult your owner's
manual
for complete
details.
P/No. DC68-O289gA-O1

Advertisement

loading

Summary of Contents for Kenmore 40289032011

  • Page 1 Size : 420 X 297 (ram) REMOVE PACKING MATERIAL CONNECT GAS SUPPLY FINAL CHECKS For electric dryers only. Use the following checklist to ma ke sure you have complet Cut the straps oil he carton and lift the carton off the drye* For gas dryers proceed to step #30 on the IdL...
  • Page 2 CONEXlON D EL SUMINISTRO DEGAS RETIRO DE LOS MATERIALES DE EMBALAJE COMPROBACIONES FINALES $61o pare secadoras el6ctricas. Pare secadoras a gas, precede al paso #3o que aparece Utilice la siguiente lista de vedficaci6n para asegurarse Carte bs coes e:/e] embalaje de cartTn y sep6relo de b secede a a la izquierda 561o pare modelos a gas...

This manual is also suitable for:

4029903201140289032012402990320124028903201040299032010