Fenton S1000A User Manual page 17

S series line-interactive ups 1000va, 1500va and 2000va
Table of Contents

Advertisement

Item
Symbol
1.
2.
3.
4.
5.
6.
7.
HIGH
8.
LCD indicator table (1)
Indication
Over load
Load level
UPS is loaded
Normal mode
Battery mode
Test mode
Buck mode
Boost mode
Timer is enabled
Thermal alarm
The loading exceeds the rating of UPS.
The higher the loading is, the more bars will
illuminate.
When "Green Mode" is enabled, this symbol will display
if the loading is over 30W (approximately), and
disappears when it's under 25W (approximately). If
"Green Mode" is disabled, the symbol will always
display.
1. The sine wave symbol will display steadily
without battery symbol when UPS is in the
normal mode.
1. The sine wave symbol and battery symbol will
blink when the UPS is in back-up (inverter)
mode.
1. The sine wave symbol will display steadily
with blinking battery symbol when the UPS is
in testing mode.
The AVR (Auto Voltage Regulator) is reducing
the output voltage of the UPS (when the input
voltage is too high), and the sine wave symbol,
as mentioned in item 4, will also display steadily
to indicate that the output is in the normal mode.
The AVR is increasing the output voltage of the UPS
(when the input voltage is too low), and the sine
wave symbol, as mentioned in item 4, will display to
indicate it's in the normal mode
This symbol will show up in the following
situations:
1. A turn-on / turn-off schedule has been set using the
monitoring software.
2. The Green Mode is enabled and the loading is
under 25W (approximately). The UPS will turn
itself off automatically in 30 seconds.
The temperature inside the UPS is over 55℃. If the
user does not reduce the load, the temperature will
continue to rise and the UPS will shut down
automatically at 60℃.