Exhaust System Requirements - Kenmore 41794252500 Installation Instructions Manual

Gas & electric dryer
Table of Contents

Advertisement

Available languages

Available languages

EXHAUST
SYSTEM
REQUIREMENTS
Use only 4 inch (! 0.2 cm) diameter (minimum) rigid or
flexible metal duct and approved vent hood which has a
swing-out damper(s) that open when the dryer is in
operation. When the dryer stops, the dampers automatically
close to prevent drafts and the entrance of insects and
rodents. To avoid restricting the outlet, maintain a minimum
of 12 inches (30.5 cm) clearance between the vent hood
and the ground or any other obstruction.
The following
are specific requirements
for proper and safe operation
of your dryer. Failure to
follow
these instructions
can create excessive drying
times and fire hazards.
Do not use plastic flexible duct to exhaust the dryer.
Excessive lint can build up inside exhaust system and
create a fire hazard and restrict air flow. Restricted air flow
will increase dryer times. If your present system is made up
of plastic duct or metal foil duct, replace it with a rigid or
flexible metal duct. Ensure the present duct is free of any
lint prior to installing
dryer duct.
If the dryer is not exhausted
outdoors,
some fine
lint will be expelled into the laundry area. An
accumulation of lint in any area of the home (:an create a
health and fire hazard. The dryer exhaust system MUST
be exhausted
to the outside of the dwelling
r.
Do not allow combustible
materials (for example:
clothing,
draperies/curtains,
paper) to come in contact
with exhaust system. The dryer MUST NOT be exhausted
into a chimney, a wall, a ceiling, or any concealed space of
a building which can accumulate lint, resulting in a fire
hazard.
Exceeding the length of duct pipe or number of
elbows allowed
in the "MAXIMUM
LENGTH" charts can
cause an accumulation of lint in tile exhaust system.
Plugging the system could create a fire hazard, as well as
increase drying times.
Do not screen the exhaust ends of the vent system,
nor use any screws or rivets to assemble the exhaust
system. Lint can become caught in the screen, on the
screws or rivets, clogging the duct work and creating a fire
hazard as well as increasing drying times. Use an approved
vent hood to terminate the duct outdoors, and seal all joints
with duct tape. All male duct pipe fittings MUST be installed
downstream with the flow of air.
Explosion
hazard.
Do not install the dryer
where gasoline
or other flammables
are kept or stored.
If the dryer is installed in a garage, it must be a minimum of
18 inches (45.7 cm) above the floor. Failure to do so can
result in death, explosion, fire or burns.
Number
of
90 °
Turns
o
1
2
3
4
MAX/MUM
LENGTH
of 4" (10.2 cm) Dia. Rigid Metal Duct
VENT HOOD TYPE
(Preferred)
Louvered
(10.2 cm)
6Oft
(1828
m)
52 ft
(1584
m)
44ft
(1341
m)
32ft.
(9.75 m)
28ft
(8,53 m)
(&35 cm)
48 ft (14 63 m)
40 ft (1219
m)
32 ft. (9.75 m)
24ft.
(7.31 m)
16ft
(4,87m)
Number
of
90 °
Turns
o
1
2
3
MAX/MUM
LENGTH
of 4" (10.2 cm) Dia. Flexible Metal Duct
VENT HOOD TYPE
(Preferred)
_
Louvered
(10.2 cm)
3Oft
(914
m)
22ft
(671
m)
14ft
(427
m)
NOT RECOMMENDED
(6.35 cm)
18 ft (549 m)
14 ft (427 m)
10 ft (305 m)
_
CORREC_
L
_i
INSTALL MALE
FITTINGS
IN CORRECT
DIRECTION
In installations where the exhaust system is not described
in the charts, the following method must be used to
determine if the exhaust system is acceptable:
1.
Connect an inclined or digital manometer between the
dryer and the point the exhaust connects to the dryer.
2.
Set tile dryer timer and temperature to air fluff (cool
down) and start tile dryer.
3.
Read the measurement on tile manometer.
4.
The system back pressure MUST NOT be higher than
0.75 inches of water column.
If the system back
pressure is less than 0.75 inches of water column, the
system is acceptable.
If the manometer reading is
higher than 0.75 inches of water column, tile system is
too restrictive and tile installation is unacceptable.

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

4178405250041794082500

Table of Contents