SECTION 6 - OPERATION OF GENERATOR WITH GENERATOR READY KIT

USING THE GENERATOR READY KIT WITH ULTRA SOURCE PORTABLE GENERATOR
The GUARDIAN
Generator Ready Kit gives you the ability to hook up a GUARDIAN
®
power safely and conveniently to vital items in your home including hard wired items. Included in the kit is a 5 foot electrical power
cord and a 5 foot DC signal harness. The power cord contains 4 wires (black & red), neutral (white) and ground (green) wires. At
one end are the terminal connectors. At the other end is the male connector (NEMA 14-50) which plugs into the GUARDIAN
SOURCE portable generator's control panel. To install this option, insert the terminal wire end of the power cord into the bottom
of the external connection box through the conduit clamp (not included) from the outside. Allow
about an inch of the power cord insulation to enter beyond the clamp to the inside of the box.
TIghten clamp securely. Attach ground wire (green) to the bottom of the box using the supplied
ground screw and pre-drilled hole. Connect red, black and white wires each to separate lug posts.
Make sure hold down nuts are tightened securely. The 5 foot DC signal harness allows semi-
automatic transfer switch operation. You simply attach the four-pin plug to its mating plug within
the external connection box. At the other end is a V-type connector that plugs into the 12-volt DC
receptacle on the portable generator control panel. Instructions for these items are detailed on the
following page (Page 25).
CAUTION:
If you are connecting the 5 foot power cord after the 30 foot conduit has been connected inside of the external
connection box you must match the black, red and white wires to the lugs of the wires previously placed.
(For example: black to black; red to red, etc.) Failure to match wires may result in damage to generator and house wiring.
5 FOOT DC SIGNAL HARNESS
50 AMP POWER PLUG
NEMA
14-50 Plug
24
ULTRA SOURCE PORTABLE GENERATOR CONTROL PANEL
NEMA 14-50
Receptacle
5 FOOT POWER CORD
WITH PLUG
ULTRA SOURCE portable generator to provide
®
12 Volt DC
Receptacle
EXTERNAL
CONNECTION BOX
Lug Posts
Bring power
cord through
here
GENERATOR READY KIT
ULTRA
®
Ground
Lug